- Transmit data

The measured data is output in the following format.
• Each piece data is with a comma-delimited (,).
• The terminator (the end of the data) is CR (ASCII code 0DH), LF (ASCII code 0AH).

(1) Output data format

Transmission Data is output immediately after measurement regardless of the status of
the receiving equipment (personal computer, etc.). Therefore the receiving equipment
needs to be ready to accept the data before measuring.

(2) Output data items

Order of output

Item

Header

Format

Contents

Body composition analyzer

Scale

Adult

Athlete

Child

1

1

1

1

2

Control data

Control data

{0

˜0

Fix to 16

Fix to 1

2 byte fixed length

1 byte fixed length

Control data

Control data

˜1

˜2

Fix to 1

Fix to 1

1 byte fixed length

1 byte fixed length

Model

Serial No.

MO

SN

”XXXXXX”

”XXXXXXXX”

8 byte fixed length

10 byte fixed length

ID number

Date (dd/mm/yyyy)

ID

Da

”XXXXXXXXXX”

”dd/mm/yyyy”

12 byte fixed length

12 byte fixed length

Time

Body type

TI

Bt

”hh:mm”

0 or 2

7 byte fixed length

1 byte fixed length (0: standard 2: athlete)

Gender

Age

GE

AG

1 or 2

XX

1 byte fixed length (1: male 2: female)

1 – 2 byte variable length (unit: age, right-aligned)

Height

Clothes (preset tare)

Hm

Pt

XXX.X

XX.X

4 – 5 byte variable length, to 1 place of decimals (unit: cm)

3 – 4 byte variable length, to 1 place of decimals (unit: kg)

Weight

Body fat %

Wk

FW

XXX.X

XX.X

3 – 5 byte variable length, to 1 place of decimals (unit: kg)

3 – 4 byte variable length, to 1 place of decimals (unit: %)

Fat mass

Fat free mass

fW

MW

XXX.X

XXX.X

3 – 5 byte variable length, to 1 place of decimals (unit: kg)

3 – 5 byte variable length, to 1 place of decimals (unit: kg)

Muscle mass

Muscle score

mW

sW

XXX.X

XX

3 – 5 byte variable length, to 1 place of decimals (unit: kg)

1 – 2 byte variable length (1-24)

Bone mass

TBW

bW

wW

XXX.X

XXX.X

3 – 5 byte variable length, to 1 place of decimals (unit: kg)

3 – 5 byte variable length, to 1 place of decimals (unit: kg)

TBW %

BMI

ww

MI

XXX.X

XXX.X

3 – 5 byte variable length, to 1 place of decimals

3 – 5 byte variable length, to 1 place of decimals (unit: kg)

Standard body weight

Degree of obesity

Sw

OV

XXX.X

XX.XX

3 – 5 byte variable length, to 1 place of decimals (unit: kg)

3 – 5 byte variable length, to 1 place of decimals (unit: %)

Visceral fat rating

BMR (kJ)

IF

rb

XX

XXXXX

1 – 2 byte variable length

1 – 5 byte variable length (unit: kJ)

BMR (kcal)

BMR score

rB

rJ

XXXXX

XX

1 – 5 byte variable length (unit: kcal)

1 – 2 byte variable length

Metabolic age

Rohrer’s index

rA

RO

XX

XXXX.X

2 byte fixed length

4 – 6 byte variable length

Target body fat %

Predicted weight

Fat to gain / lese

Checksum

gF

gW

gt

CS

XX

XXX.X

XXXX.X

XX

1 – 2 byte variable length

3 – 5 byte variable length

3 – 6 byte variable length

2 byte fixed length

Predicted fat mass

Impedance

gf

ZF

XXX.X

XXXX.X

3 – 5 byte variable length

5 – 6 byte variable length

2

2

2

3

3

3

4

4

4

5

5

5

3

6

6

6

4

7

7

7

5

8

8

8

6

9

9

9

7

10

10

10

11

11

11

12

12

12

13

13

13

14

14

14

8

15

15

15

9

16

16

16

17

17

17

18

18

18

19

19

19

20

20

21

21

22

22

20

23

23

21

24

24

25

26

27

25

28

26

29

27

30

28

31

29

22

32

30

23

33

35

37

31

33

35

24

26

28

10

34

36

32

34

25

27

Summary of Contents for SC-330

Page 1: ...GB REMOTE DISPLAY VERSION COLUMN MOUNTED VERSION Please read this Instruction Manual carefully and keep it handy for future reference BODY COMPOSITION ANALYZER SC 330ST Instruction manual...

Page 2: ...diseases and conditions related body weight and composition It can be used in the monitoring and prevention of conditions caused by excessive deposits of fat tissue such as diabetes hyperlipidemia cho...

Page 3: ...5Before use Safety Notes GB 4 Before use Safety Notes GB...

Page 4: ...d Components Electrode 4 positions Platform Dropper 1 item Instruction manual This manual AC adapter Power cord Hexagonal wrench 1 item Hexagon socket head bolts M5L12 4 items Printer paper Thermal pa...

Page 5: ...Setting of the printer paper Connection of Plugs Control panel Rear side of the controller AC adapter To avoid electric shock do not insert or remove the plug with wet hands To avoid electric shock do...

Page 6: ...page 22 48 Bone mass page 22 50 Basal metabolic rate BMR page 22 51 Metabolic age page 22 52 Visceral fat rating page 22 54 Rohrer s index page 22 55 Ideal body weight page 22 56 Degree of obesity pa...

Page 7: ...mber of sheets to print for the scale setting screen is displayed Enter Next 3 5 After inputting the numeric value press It returns to the setting item selection screen Enter Next Various settings Set...

Page 8: ...off for invalid To correct the input value or cancel the input epress the input is deleted CE Press and then press The ON or OFF of the Fat Healthy range selection screen is displayed Enter Next 6 5 A...

Page 9: ...eight The default is 1 on 0 off sets 0 1 cm unit input 1 on sets 1 cm unit input To correct the input value or cancel the input epress the input is deleted CE Press and then press The input unit of he...

Page 10: ...nt item preset Set with 3 1 The print items preset are ea function to set the print items of the pattern 1 3 to ON automatically at once page 19 The default is 1 pattern 1 When ON or OFF of print item...

Page 11: ...a proportion of body weight FFM Fat Free Mass is comprised of muscle bone tissue water and all other fat free mass in the body TBW Total Body Water is the amount of water retained in the body TBW is s...

Page 12: ...ng item selection screen Enter Next In the case of selecting 39 In the case of selecting the logo setting on 39 TANITA Logo 40 Category name 41 Serial number 42 Memo space 43 ID No 44 Fat mass 45 Fat...

Page 13: ...old or older Attention 25 24 3 Press to turn on the power Unit is changed by key Note 1 Press Enter Next The Step on lamp flashes When is pressed it returns to the previous screen CE Note kg mode Che...

Page 14: ...ected with the numeric keys If it is mistakenly input epress the input is deleted and it returns to the body type selection screen If is pressed in the state that the body type is not input it returns...

Page 15: ...ased on the body fat percentage page 38 How to read the display st lb mode Judgment result based on the body fat percentage page 38 9 Input the age Input it by pressing The age can be input from 5 99...

Page 16: ...rement start screen CE CE 2 1 Note 6 Select gender Press the male female selection keys to input When male or female is selected the lamp flashes on the Age If it is mistakenly input epress the input...

Page 17: ...based on the body fat percentage page 38 How to read the display st lb mode Judgment result based on the body fat percentage page 38 How to use Operating Instructions GB 32 7 Input the age Input it b...

Page 18: ...hen using as a scale 34 How to use Operating Instructions Operating Instructions Target body fat ratio Input the target body fat ratio Input it by pressing This screen is displayed if ON is set in the...

Page 19: ...played in the case that OFF is set in the setting with or without an ID page 15 The ID number can be input from 0 9999999999 If it is mistakenly input epress the input is deleted If is pressed in the...

Page 20: ...dy water percentage reading should act as a guide and should not be used to specifically determine your absolute recommended total body water percentage It is important to look for long term changes i...

Page 21: ...reading for the user based on the impedance measurement This method has been medically validated using indirect calorimetry measuring the breath composition Reliability on equation for Basal Metaboli...

Page 22: ...ng caught in the gaps The measured weight is not stable The paper comes out however nothing has been printed Troubleshooting Symptom Please check Please check the following before asking for repair Tu...

Page 23: ...cable when the equipment is connected to an external computer Communication standards Communication method Signal speed Data bit length Parity Stop bit Flow control Terminator Compatible with EIA RS...

Page 24: ...e of decimals unit kg 3 4 byte variable length to 1 place of decimals unit Fat mass Fat free mass fW MW XXX X XXX X 3 5 byte variable length to 1 place of decimals unit kg 3 5 byte variable length to...

Page 25: ...electrodes on the tips of the toes of both feet and voltage is measured on the heel of both feet The current flows into the upper limbs or lower limbs depending on the body part s to be measured Visc...

Page 26: ...rd changes in impedance is not stable depending on the type and rigorousness of the exercise 4 If possible urinate before taking measurement 5 For repeated measurements measure at the same hour as muc...

Page 27: ...Rate BMR is more determined by the Fat Free Mass FFM than by the body weight Persons of a given body weight with a higher FFM will have a higher BMR and that from the aspect of evaluating the body com...

Page 28: ...kg increments 0 20 lb 0 2 lb increments 0 270 kg 0 1 kg increments 0 42 st 12 lb 0 2 lb increments 3 75 0 1 increments 0 1 kg 0 2 lb increments 0 1 kg 0 2 lb increments 0 1 kg 0 2 lb increments 0 1 kg...

Page 29: ...Copyright 2008 TANITA Corporation All Rights Reserved SC3307651 GB...