How to use (Scale)

17

H

o

w

 t

o

 u

s

e

 

(S

c

a

le

)

2

Check that the Weight only mode is
selected (

P.13).

3

Input the clothes weight.

1) by 

or 

,

2) and 

key

a

clear the input.

1

Press 

to turn on the power.

4

5

Step  on  the  platform,  after  "Step
on" flashing. 

Measurement completion.

Summary of Contents for SC-240MA

Page 1: ...ude 2 000m ASL Pressure Range of Environment 86kPa 106kPa Temperature Range of Environment 10 C 60 C Range of Relative Humidity 10 90 without condensation To avoid malfunctions avoid storing the equipment where there is direct sunlight significant temperature changes the risk of dampness a large amount of dust in the vicinity of fires or where there is the risk of receiving vibrations or shocks St...

Page 2: ...tty liver It can be used in the monitoring of changes in individuals body composition related to differences in the ratio of fat tissue to lean It can be used to assess the effectiveness of individuals nutrition and exercise program mers both for health and physical fitness Efficacy 1 This product is simple to use and requires no specialized facilities or expertise to take meas urements 2 Measurem...

Page 3: ...Display Panel Operation Keys 9 Preparation 10 Power supply 11 Various setting 12 Before use How to use 13 Mode selection 13 Body composition analyzer 14 Scale 17 Scale Weight Lock Mode 18 BMI Mode 19 How to use Various criteria 20 Troubleshooting 22 Specifications 24 When necessary ...

Page 4: ...o ensure the safe operation of this equipment This device must not be used on subjects with pacemakers or other mechanical implants This device passes a weak electrical current through the body which could inter fere with and cause the malfunction of electrical medical implants resulting in serious repercussions Do not handle the plug with a wet hand Such action may result in electric shock fire o...

Page 5: ... with appropriate disinfectant after each use Continually monitor both the subject and the equipment for anomalies Should an anomaly with the subject or the equipment be discovered take appropriate action such as stop ping the equipment while ensuring the safety of the subject Be sure to use the included AC adapter Do not interpret analysis results yourself including evaluating measurements and fo...

Page 6: ...nsmitters such as mobile phones which may affect readings Use the device under the same conditions and in the same position as much as possible to track changes Readings are greatly affected by the level of hydration and position of the body Please use at the same time each day under the same conditions and in the same body position Avoid measuring in locations of greatly differing temperature May...

Page 7: ...nnector ends for damage or contamination All safety related labeling for legibility All accessories sensors electrodes etc for wear or damage 3 Visually inspect the following at least monthly Mounting screws on equipment Update settings replace items or call for service as necessary according to the results of the visual inspections Do not use the unit if you see any signs of damage Equipment that...

Page 8: ...vel Gauge Adjustable feet Platform BatteryBox Adjustable feet Electrode For accurate measurement place the machine as level as possible Rotate the adjustable feet in 4 positions for adjustment so that the bubble of the level gauge reach the centre Circle Air bubble In the state that the level gauge is viewed from the top Level gauge check ...

Page 9: ...ansformer Thermal fuse 115 C Caution Refer to the attached information Date of manufacture For indoor use only Before use Names and Functions of Display Panel Operation Keys This equipment and the attached instruction manual use expressions including terminology sited in the NAWI directive Please review the following terminology explanations before use Max Maximum capacity This shows the maximum w...

Page 10: ...urement Measurement may not be possible on the unstable environment During weight measurement please don t touch any connecting cable such as an AC Adapter cable and PC communication cable to avoid causing unstable scale installation Please change the batteries LR6 AA careful ly to avoid dropping them on your feet Ensure that the batteries are inserted with the correct polarity If the polarity is ...

Page 11: ...efore use Power supply When turn on the power Emergency Shut Down or Press to turn on the power When turn off the power Press to turn off the power For emergency keep clear around the outlet during operating this equipment ...

Page 12: ...d key 3Select the setting items 1 by or 2 and key SET1 Set ON OFF of the beep sound 0 off or 1 on SET2 Set ON OFF of the athlete selection 0 off or 1 on SET3 Set the automatic determination time when inputting input range 0 9 seconds 0 automatic determination function deactivate SET4 Set the automatic power off time 0 5 10 30 60 minutes 0 automatic power off function deactivate ...

Page 13: ...ction 13 1Press to turn on the power Model name is displayed is displayed Body composition analyzer Mode is selected by key Body composition P 14 Scale P 17 Scale Weight lock P 18 Scale BMI Mode P 19 How to use Mode selection ...

Page 14: ...ody composition analyzer 2Check that the Body composition analyzer mode is selected P 13 3Input the clothes weight 1 by or 2 and key a clear the input 4Select the Body type and Gender 1 by or 2 and key a return to previous status 1Press to turn on the power ...

Page 15: ...GB 15 How to use Body composition analyzer 5 Input the height 1 by or 2 and key a return to previous status 6 Input the age 1 by or 2 and key a return to previous status ...

Page 16: ...position analyzer Continue 16 How to use Body composition analyzer a Clear the displayed result 7 8 Step on the platform with bare feet after Step on flashing Measurement completion Body fat Body weight BMI Total body water ...

Page 17: ...ow to use Scale 2Check that the Weight only mode is selected P 13 3Input the clothes weight 1 by or 2 and key a clear the input 1Press to turn on the power 4 5 Step on the platform after Step on flashing Measurement completion ...

Page 18: ...hat the Weight only mode Weight lock mode is selected P 13 3Input the clothes weight 1 by or 2 and key a clear the input 1 Activation of Weight lock function Press to turn on the power 4 5 Step on the platform after Step on flashing Measurement completion a Clear the displayed result ...

Page 19: ... is selected P 13 3Input the clothes weight 1 by or 2 and key a clear the input 4 1Press to turn on the power Input the height 1 by or 2 and key a return to previous status 5 6 Step on the platform after Step on flashing Measurement completion a Clear the displayed result ...

Page 20: ...risk for health problems Obese high above the healthy body fat range Greatly increased risk of obesity related health problems Criteria based on body fat percentage Body fat percentage is the amount of body fat as a proportion of your body weight Reducing excess levels of body fat has shown to reduce the risk of certain conditions such as high blood pressure heart disease diabetes and cancer The c...

Page 21: ...ge reading should act as a guide and should not be used to specifically determine your absolute recommended total body water percentage It is important to look for long term changes in total body water percentage and maintain a consistent healthy total body water percentage Drinking a large quantity of water in one sitting will not instantly change your water level In fact it will increase your bo...

Page 22: ... repair Turn off the power and remove the items on the platform and turn on the power again and then redo the measurement How to measure Zero point error Impedance measure ment error Measure with bare feet When the soles of your feet are dry drop water for about 0 5 ml with the attached dropper on the electrodes before measurement Check the input information Display part Nothing is displayed even ...

Page 23: ...GB 23 When necessary Troubleshooting ...

Page 24: ...alysis 50 kHz 90µA 150 1200Ω Strain Gauge Load Cell 200kg 0 1kg 0 10kg 0 1kg increments Female Male Standard Athletic 5 99 years Standard 18 99 years Athletic 90 249cm 1cm increments 0 200 0kg 0 1kg increments 3 75 0 1 increments 0 1 increments 15 85 0 1 increments USB 4 7kg 341x437x54mm Specifications 2012 2016 TANITA Corporation SC2407601 3 1604CF GB This product meets the following requirements...