Tanita PW-630MA Instruction Manual Download Page 4

GB

GB

Before

use

(cautions

for

safety)

7

• For raise

(1) When the scale is lifted after measurement, AC Adapter and Controller must

be taken off.

They may be damaged when moving.

2 The Controller Bag is put in the handle.

While moving the scale, the Controller Bag should be hung on the handle of
scale. Controller and AC Adapter should be put into the bag.

3 Hold the handle to lift up the scale slowly. It is easier to lift the scale by using

Caster of scale. 

Please stand outside the handle of scale, then lift up.
It is likely to throw your back when forcibly lifting.
* Especially, when the scale is raised, it may fall down due to the heavy weight

of the scale.

• For move

1 Hold the handle and the Caster is used and it moves aside.

Please make sure that there is no obstacle on the floor and watch out for the
slope.

2 It is done centering on the Caster of the middle, and the Platform can be

turned.

It is easier to move the scale by using the Caster.

• For installation

1 Hold the handle, the Caster side is made the fulcrum and it is take down

calmly.

Please be careful for dropping the scale on your feet.

2 All the adjustable feet in four positions should be touched with the floor properly.

Unless all four adjustable feet come in contact with the floor, it may not measure correctly due to equipment malfunction.

3 Please make sure there is no obstacle between adjustable feet and the floor.

Correct measurement may become impossible.

• Do not force yourself to measure by your self.

Receive assistance from a caregiver.

When this equipment is raise, move, and installation, it is done in more
than two people.

Handle

Rail

Caster

In case of the use

Explanation of terminology

This equipment and the attached instruction manual use expressions including the
terminology used in NAWI Directive (90/384/EEC).  Read the following explanation
of terminology before use.

• Max (Maximum capacity)

This shows the maximum weight that can be measured by the scale.

[Example]

In the case of Maximum capacity 300kg, it can measure up to 300 kg.
* One exceeding the weighing capacity cannot be measured.

• e (Minimum Graduation)

This shows the amount of one scale mark.  In the case of a digital display, this shows the interval of
the numeric value to change.

[Example]

In the case of Minimum Graduation 0.1 kg, the display increases and decreases at an interval of 
0.1 kg.

• Extend Minimum Graduation

This is the amount of the scale mark that can display more finely than the Minimum Graduation.
The display range is up to 1/10 of Minimum Graduation (this cannot be used for actions of
transaction certification).

• Tare

The container, bag, wrapping paper, etc., used when measuring weight is called “tare”.
And to measure the net-weight after subtracting the weight of the tare is called "tare weighing."
Moreover, to measure the net-weight after subtracting the weight that is known beforehand without measuring the weight of the
tare at the time of the measurement is called “preset tare”.

BMI

This is an abbreviation of Body Mass Index, and is calculated by 

. “22” is said to produce fewer illnesses.

weight (kg)

height (m)

2

Before

use

(cautions

for

safety)

6

Safety Notes 

(continued)

To measure correctly

• Do not use mobile phones or microwave therapy equipment near this equipment.

It may not measure correctly due to equipment malfunction.

• Do not step on the rail.

Correct measurement may become impossible to measure precisely. It may not be measured weight correctly.

Do not measure at a place where the temperature fluctuates greatly.

Errors may be observed in the measured value.  In the case to move to a place with a temperature
difference of 20˚C or more, leave it before use for 2 hours or more after moving.

Handle

Controller Bag

Hook

Summary of Contents for PW-630MA

Page 1: ...GB Wheel Chair Scale PW 630MA INSTRUCTION MANUAL Please read this Instruction Manual carefully and keep it handy for future reference ...

Page 2: ...rce 5 To measure correctly 6 In case of the use 6 Explanation of terminology 7 Part names 8 Preparation 10 Various settings 12 Applications This equipment has been calibrated as a precision weighing instrument and can be used to certify weights and or business transactions It can be used to obtain reference data during medical examinations such as periodic checkups and can help the prevention of o...

Page 3: ...persons Physically disabled persons should not attempt to take measurements alone but instead should have their caretakers assist them in using the device This symbol indicates the possibility of serious injury if the product is mishandled or instructions are ignored This symbol indicates the possibility of physical injury or equipment damage if instructions are ignored This symbol indicates gener...

Page 4: ...uding the terminology used in NAWI Directive 90 384 EEC Read the following explanation of terminology before use Max Maximum capacity This shows the maximum weight that can be measured by the scale Example In the case of Maximum capacity 300kg it can measure up to 300 kg One exceeding the weighing capacity cannot be measured e Minimum Graduation This shows the amount of one scale mark In the case ...

Page 5: ...P ON mark Ready mark Indicates that the scale is ready to begin measurements HEIGHT mark Unit of height Indicates the height is set BMI mark Indicates when BMI mode is on WEIGHT LOCK mark Indicates when the measurement is stabilized Display Unit On Display Unit Off Direct current Class II Equipment Type B applied part Input Output Zero reset Turn on the tare weighing function Caution Refer to the ...

Page 6: ...side AC Adapter Connecting the platform and the Controller 1 Connect the Platform and the Controller with the connecting cable When connecting the Platform and the Controller do not hold the movable part of the connector but hold the slightly lower part to insert it Fig 1 When disconnecting the connector from the Platform move the movable part of the connector in the arrow direction indicated on t...

Page 7: ...anged refer to page 13 Change of setting 8 Setting of the print items This is set to on at the time of shipment 10 Setting of the Weight lock time This is set to 10 seconds at the time of shipment 11 Setting of the weight Lock release function This is set to on at the time of shipment 7 Setting of the number of sheets to print This can be set to 0 to 9 however this is set to 1 sheet at the time of...

Page 8: ...ecember 31 2099 5 0 4 1 8 1 2 0 6 0 3 Setting of automatic reading of the preset tare The preset tare is a function to input the tare previously For example if the normally used wheelchair is the same register the weight and the tare does not have to be inputted every time In this equipment 2 tare values of memory 1 and 2 can be registered The function to read in and utilize the previously used pr...

Page 9: ... this case it skips the steps 9 and 10 and moves to the screen of step 11 Setting of the weight lock time Up to 9 sheets at maximum can be printed out Input After input it moves to the next setting screen print items or weight lock time 8 Setting of the print items 9 Set the print items For each number input either or with the numeric key no 1 TANITA no 2 Model name no 3 Date and time no 4 ID numb...

Page 10: ... that off is set in Set ON OFF of the ID number page 16 this screen is not displayed The ID number increases 1 for every measurement And once the power is OFF it starts from 0000000001 The ID number can be inputted in the range of 0 9999999999 When is pressed during input the non inputted digits are filled with 0s When the input is mistaken press The input is deleted Note Input the ID number This ...

Page 11: ...result it is printed out according to setting After that it automatically returns to the ID input screen In the case that the preset tare is not used the s to show that the tare is flashes In the case that the BMI display is set to OFF in the Setting of the BMI page 16 the BMI is not displayed However in the case that 0 sheets is set in the Setting of the number of sheets to print page 17 and all ...

Page 12: ... numeric keys Note In the case to measure the weight In the case to use numeric keys Only once BMI mode The BMI can be measured even in the case that the BMI mode is not set BMI score will be effective only once 1 In the case that the power is on move to the 2 Change to the BMI mode Press According to the contents of the initial setting the screen displayed after the all display flashing varies No...

Page 13: ...rtification Use the value only for reference Note Extend function Zero reset In the case that the display is not 0 0 kg in the state that nothing is on the Platform and a tare is not set the display is returned to the correct state 1 Check that the display is not 0 0 kg in the state that nothing is on the Platform and a tare is not set Check the display 2 Press The display is returned to 0 0 kg Ze...

Page 14: ...he Print roll paper Return the Print roll paper by following the procedure in page 11 Loading the Print roll paper Return the Print roll paper cover to the proper position Press the Print roll paper cover down slowly as the catches of the cover go into the guide holes page 11 Please pay careful attention to avoid injury from the sharp edge Please turn off the machine before clearing Paper jams RS ...

Page 15: ...e status of the personal computer or other device at the receiving end For that reason the personal computer or other device to which data will be transmitted must be put in a reception ready status before measurement RS 232C Interface Instructions continued PC mode PC mode 1 This is a mode to communicate from a personal computer etc Connect the personal computer and the Controller and turn on the...

Page 16: ...D LF CR 5 4 3 2 1 0 0 0 0 0 D 4 Confirm settings PC e e PW 630 If setting is completed PW 630 e e PC If setting is incomplete PW 630 e e PC LF CR 0 0 0 0 0 0 0 0 0 0 D I 5 D 0 m H 3 D 0 0 t P 0 D LF CR 5 4 3 2 1 0 0 0 0 0 D I 5 D 1 7 1 m H 3 D 0 0 3 t P 0 D LF CR D 5 Example of Use The wheelchair scale is used remotely as follows Start measurement BMI mode PC e e PW 630 After measurement preparati...

Page 17: ...ions Blade part Top view When necessary cautions for safety 32 Troubleshooting Error display E01 E11 E12 E13 E14 is issued during measurement and it cannot be measured Error display is issued during weight measurement and it cannot be measured Product specifications BMI Model number Weight measuring part Measurement System Maximum capacity maximum weighing Minimum Graduation minimum display Height...

Page 18: ...em 2 Change of setting Press on the setting screen The input screen of the date and time setting is displayed The top line is for the year and the bottom line for the month 3 4 Setting of the date and time above in the step 2 Returns to the measurement screen When all the input is completed it automatically returns to the measurement screen 5 3 Set the automatic reading of the preset tare Input ei...

Page 19: ...GB Copyright 2005 TANITA Corporation All Rights Reserved ...

Reviews: