5.5
Lowering the Jack
Do not
drop loads onto the jack. If the jack is inadvertently
subjected to a shock load, remove from service and have it
checked by the manufacturer or service agent.
To lower the jack, first remove the operating lever from the
operating quadrant and place it into the release screw.
Turning this anti-clockwise will allow the ram to descend. The
amount this is rotated will control the speed of descent; only
open a very small amount (approx. 5°) at first.
Figure 9 - Closing the Release Valve Screw