V12/2009

EU Decleration of Conformity

SA20, SA40, SA70, SA100

Please check before using

Power supply

The AC line voltage must be in ac-

cordance with the following:
Voltage: ~230V±10%
Frequency: 50Hz/60Hz

Mode selection

The dip switches (located on the rear 

panel) confi gure the amplifi er for eit-

her stereo, parallel or bridged mono 

mode. Factory default setting is Ste-

reo Mode.

Stereo mode
In Stereo Mode, both channels ope-

rate independently, with their input 

attenuators controlling their respec-

tive levels. Signal at channels A´s 

input produces output at channel A´s 

output, while signal at channel B pro-

duces output at channel B´s output. 

Recommended minimum nominal 

load impedance for stereo operation 

is 4 ohms per channel.

Parallel mode
When set to Parallel Mode, a signal 

applied to A´s input will be amplifi ed 

and appear at both channels outputs. 

Only channel A input may be used.

Bridged mono mode
Bridged mono mode straps both am-

plifi er channels together to make a 

very powerful, single - channel amp. 

One channel “pushes“ and the other 

“pulls“ equally, doubling the power. 

Signal is applied to the Channel A 

input only. Signal level is determined 

by CH A level control.

Operating instructions

- Clean or replace dust fi lter

From time to time or after using this 

unit in dusty environments the 
dust fi lter of the amplifi er should be
cleaned or replaced. To take off the 

front panel, remove the 
corresponding Phillips-head screws.
Take out the fi lter foam, clean or re-

place it and assemble the front 
panel again.
Clean the fi lter foam with warm wa-

ter and a little bit of rinsing agent. 
Take care to dry the the foam
completely before reassembling it.