Page | 52
Figure 38 - CADS Custom Application Configuration
These warning and alarm level settings determine when the status will show, green, amber and
red. You can set upper and lower limits for oil condition, temperature and rate of change.
These warning and alarms levels are optional settings and you can set the levels according to
your specifications. The correct levels will depend on your objectives and application, in order
to create a bespoke solution we would recommend logging data for one oil change cycle or six
to eight weeks and then sending the data to
you.
8.2.6.7
Write Settings
Once your required settings are selected, use the arrow to proceed. A pop-up message will
request confirmation that new settings should be sent to the device. Once confirmed, the
settings will be written to the device.
Note: Do not disconnect device until CADS has displayed confirmation that the
configuration has been successful.