4
M
ounting
4
.
1
G
eneral instructions
M
ake sure that all parts of the instrument exposed to the process
,
in
particular the sensor element
,
process seal and process
fi
tting
,
are
suitable for the existing process conditions
.
T
hese include above all
the process pressure
,
process temperature as well as the chemical
properties of the medium
.
Y
ou can
fi
nd the speci
fi
cations in chapter
"
T
echnical data
"
or on the
type label
.
L
ateral movements of the transmitter can cause measurement errors
.
F
or this reason
,
mount the instrument in a calm area or in a suitable
protective tube
.
T
he connection cable has a capillary for atmospheric pressure
compensation
.
T
herefore lead the cable end into a dry environment or
a suitable terminal housing
,
for example
VEGABOX
02
or
VEGA
-
DIS
62
.
F
ig
.
3
:
M
ounting example
:
VEGAWELL
52
in a pump shaft with breather housing
VEGABOX
02
S
uitability for the pro
-
cess conditions
M
ounting position
P
ressure compensation
M
ounting example
VEGAWELL
52
•
4
…
20
m
A
11
4
M
ounting