• If there is a possibility that units with the same frequency channel will be in wireless communication at the
same time, please make sure to make changes to the frequency channels so they are not the same.
Important Notices and Disclaimers
In order to properly use this product, please carefully read all documents that accompany the product
before using. T&D Corporation accepts no responsibility for any malfunction of and/or trouble with this
product or with your computer that is caused by the improper handling of this product and will deem
such trouble or malfunction as falling outside the conditions for free repair outlined in the attached
warranty.
• All rights of the attached documents belong to T&D Corporation. It is prohibited to use, duplicate and/or ar-
range a part or whole of the attached documents without the permission of T&D Corporation.
• Microsoft and Windows are registered trademarks of Microsoft Corporation in the United States and/or other
countries.
• Windows Vista is either a registered trademark or trademark of Microsoft Corporation in the United States and/
or other countries.
• All registered trademarks, company names, product names and logos mentioned herein or for products being
used are the property or registered property of T&D Corporation or of their respective owners.
• Specifications, design and other contents outlined in the attached documents are subject to change without
notice.
• Please follow the safety precautions outlined in the attached documents carefully. We cannot guarantee nor
are we responsible for safety if this product is used in any manner other than was intended.
• On-screen messages in the attached documents may vary slightly from the actual messages.
• Please notify the shop where you purchased this product or T&D Corporation of any mistakes, errors or unclear
explanations in the attached documents.
T&D Corporation accepts no responsibility for any damage or loss of income caused by the use of our product.
• Accompanying documents cannot be reissued, so please keep them in a safe place.
• Please read the warranty and provisions for free repair carefully.
Compliance Information
CE Statement
This device complies with technical specifications required under EN 301 489
(with battery and AC Adaptor), EN 300-220, and EN 60950-1.
Important Notices
Wireless products cannot be used in countries other than where those products have been approved for
use, according to that country's wireless regulations.
T&D Corporation shall in no manner whatsoever take responsibility for the usage of these products, nor
be liable in any manner for legal consequences stemming from the usage of these wireless products in
unapproved areas.
For product information or questions contact us at:
817-1 Shimadachi Matsumoto, Nagano 390-0852 JAPAN
Fax: +81-263-40-3152 E-mail: [email protected]
http://www.tandd.com/
We have opened an English Website for your convenience. Here you can find information about our
company, news, products, upcoming events, software and Introductory Manual downloads, as well as,
ther support. Please stop by and see what we have to offer.
Specifications
Unit type
RTR
-501 / RTR-501L
RTR
-502 / RTR-502L
RTR
-503 / RTR-503L
RTR
-507 / RTR-507L
Measurement Channels
Temperature 1ch ( Internal )
Temperature 1ch ( External )
Temperature 1ch, Humidity 1ch
( External )
1 Temperature Channel
( External )
1 Humidity Channel
( External )
Sensor
Thermistor
Thermistor
Thermistor
Polymer Resistance
Platinum Resistance
Electrostatic Capacitance
Measurement Units
°C, °F
°C, °F
°C, °F
%RH
°C, °F
%RH
Measurement Range
-40 to 80°C
-60 to 155°C
0 to 55 °C
10 to 95 %RH
-30 to 80 °C
0 to 99 %RH
Accuracy
Avg.±0.5 °C
Avg.±0. 3°C
[
-20 to 80 °C ]
Avg.±0.5 °C
[
-40 to -20 °C / 80 to 11 0 °C ]
Avg.±1.0 °C
[
-60 to -40 °C / 110 to 155 °C ]
Avg.±0.3 °C
±5 %RH
[ at 25 °C, 50 %RH ]
±0.3°C [ at 0 to 50 °C ]
±0.5°C [ at all other
temperatures ]
±2.5 %RH [ at 25 °C, 10 to 85 %RH]
±4.0 %RH [ at 25 °C, 0 to 10 % or 85
to 99 %RH ]
At temperatures other than 25 °C and
≥ 0 °C, add ±0.1 %RH per degree of
difference from 25.
Humidity Hysteresis: ±1.5 %RH or
lower (*1)
Measurement Resolution
0.1°C
0.1°C
0.1°C
1 %RH
0.1 °C
0.1 %RH
Responsiveness
Thermal Time Constant:
Approx. 15 min.
Approx. 25 min. ( L Type )
Response Time ( 90% ):
Approx. 35 min.
Approx. 47 min. ( L Type )
Thermal Time Constant:
Approx. 30 sec. ( in air )
Approx. 4 sec. ( in agitated water )
Response Time ( 90% ):
Approx. 80 sec. ( in air )
Approx. 7 sec. ( in agitated water )
Response Time ( 90% ):
Approx. 7 min.
Response Time ( 90% ):
Approx. 7 min.
Response Time (90%):
Approx. 20 sec.
Logging Capacity
16,000 readings
8,000 data sets ( One data set consists of readings for multiple channels. )
Recording Interval
Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min.
Recording Mode (*2)
Endless ( Overwrite oldest data when capacity is full ) or One Time ( Stop recording when capacity is full )
Communication Interfaces
- Wireless Communication ( Short Range Radio Communication )
ETSI EN 300 220 ( Frequency Range: 869.7 to 870 MHz, RF Power: 5 mW )
- Optical Communication ( proprietary protocol )
Wireless Transmission Range
Approx. 150 meters (500 ft) if direct and unobstructed
Power
Lithium Battery: LS14250 (*3) x 1 L Type: Large Capacity Battery Adaptor Kit ( RTR
-500B1 ) (*4)
External Power Adaptor Kit ( RTR
-500A2: sold separately ) (*5)
Battery Life (*6)
About 10 months
L Type: About 4 years
Dimensions
H 62 mm x W 47 mm x D 19 mm
L type: H 62 mm x W 47 mm x D 46.5 mm
( excluding protrusions and sensor )
Antenna length: 24 mm
Weight
Approx. 56 g
L Type: approx. 109 g
( including battery / excluding sensor )
Operating Environment
-40 to 80°C
(
-30 to 80°C during wireless communication )
-40 to 80°C
(
-10 to 80°C during wireless communication ) (*7)
Waterproof Capacity
IP67: Immersion proof
IP64: Splash proof
(rated for use in daily life) (*8)
IP64: Splash proof ( rated for use in daily life ) (*8)
Note: Sensor is not water resistant.
Compatible Base Units
RTR
-500, RTR-500NW/500AW, RTR-500DC, RTR-500GSM
RTR
-500, RTR-500NW/500AW, RTR-500DC
*1: When used in environments where temperature and humidity are over the values of 50°C 75%, 60°C 50%, 70°C 35%, and 80°C 25%, sensor hysteresis may fluctuate by values greater than ±1.5%RH.
Under certain circumstances, it may take some time to return to normal measurement capability.
*2: Only "Endless" is available when using RTR-500W for Windows or RTR-500GSM for Windows.
*3: The included lithium battery ( LS14250 ) is not sold in stores. Please purchase the optional battery set ( TR-11P2 ) for replacement.
*4: When using RTR-500B1 it is necessary to purchase Lithium Battery ( LS26500 ). For details, contact your local authorized distributor.
*5: RTR-500A2 should not be used with the RTR-501, as it will cause the RTR-501 to display a higher than actual temperature reading of up to 3°C.
*6: Battery life varies depending upon the ambient temperature in which it is used, the recording interval, the frequency of communication, and the battery performance. All estimates are based on operations
carried out with a new battery and are in no way a guarantee of actual battery life.
*7: When wireless communication is performed in an environment below -10°C, measurement may fail or may not be accurate.
*8: This is the waterproof capacity of the data logger with the sensor connected.
The specifications listed above are subject to change without notice.
Cautions about using the Included Sensors
Temperature Sensor: TR-5106
Waterproof
Materials: Thermistor Fluoropolymer-coated Electrical Wire
• Do not bend or press the last 5 cm to the tip of the sensor, as this
may damage it.
• If the fluoropolymer-coated section of the sensor and/or the
cable has a defect or tear, the waterproof capacity will be lost.
Inspect it before operation.
• Insert the sensor tip to at least 5 cm or more to obtain on
accurate temperature measurement.
• Only use the sensor within the sensor temperature durability
range ( -70 to 180˚C ).
Temperature/Humidity Sensor: TR-3310
Materials: Temp/Humidity Sensor Polypropylene Resin Vinyl Chloride
Coated Electrical Wire
• This sensor is not water resistant. Do not use it in places subject
to condensation or dampness. If the sensor gets wet, immediately
remove the sensor from the unit and wipe it with a clean cloth as
soon as possible. Then allow the sensor to dry in normal room
temperature before using it again.
• Do not use the sensor in places subject to corrosive gases or
organic solvents.
• Do not expose the sensor to a strong impact. This may adversely
affect measurement accuracy and cause damage or malfunction.
• Continued use may cause a decrease in the sensor's accuracy
and sensitivity even under normal operational conditions. Periodic
calibration may be required.
• When the sensor is not to be used for a long period of time, store it
at normal temperature and humidity.
High Precision Temperature/Humidity Sensor:
HHB-3101
Materials: Temp/Humidity Sensor Polycarbonate Vinyl Chloride Coated
Electrical Wire
• This sensor is not water resistant. Do not use it in places subject to
condensation or dampness. If the sensor gets wet, immediately remove the
sensor from the unit and wipe it with a clean cloth as soon as possible. Then
allow the sensor to dry in normal room temperature before using it again.
• Do not use the sensor in places subject to dust, corrosive gases or organic
solvents.
• Do not expose the sensor to a strong impact. It may adversely affect
measurement accuracy and cause damage or malfunction.
• Continued use may cause a decrease in the sensor’s accuracy and
sensitivity by about 1% per year even under normal operational conditions.
• When used in environments where temperature and humidity are over
the values of 50˚C 75%, 60˚C 50%, 70˚C 35%, and 80˚C 25%, sensor
hysteresis may fluctuate by values greater than ±1.5%RH. Under certain
circumstances, it may take some time to return to normal measurement
capability.
• When the sensor is not to be used for a long period of time, please store it at
normal temperature and humidity.
Explanation of Symbols
<Warning Symbols>
DANGER
These entries are actions that, if taken, may cause serious personal
physical damage or death.
CAUTION
These entries are actions that if taken may lead to physical injury or
damage to persons or things.
<Picture Symbols>
Denotes an important
warning or caution.
Denotes a
forbidden action.
Denotes an action that
should be carried out.
DANGER
To Prevent Serious Accidents
Do not disassemble, repair or modify the unit and accessories.
Do not use the unit in any environment that is exposed to chemicals and harmful gases.
Doing so may cause corrosion and/or other danger to the unit. Also, coming in contact with
hazardous substances may cause bodily harm to the user or people nearby.
If water or a foreign object enters the case, immediately remove batteries and stop using it.
Do not insert or replace batteries with wet hands.
This product has been designed for private and/or industrial use only. It should not be used in
situations where strict safety precautions are necessary such as with medical equipment, or
in systems directly or indirectly connected with human life or well-being.
Do not drop or expose the unit to a strong impact.
Do not cut or process the sensor cables. Also, do not twist, pull on or swing any of the
cables.
To prevent damage to the unit from static electricity, remove static electricity from your body
by touching metal around you (such as a door knob and window frame) before touching the
unit.
Please be careful not to touch the unit during or after use in overly hot or cold environments.
It may cause burns or frostbite.
Place and store the unit and accessories out of the reach of children.
Further, T&D is not responsible for any damage, malfunction or trouble, whether direct or
indirect, caused by the use of our products.
Do not use any power or sensors other than those specified by T&D Corporation.
If the unit produces heat, emits smoke or a strange smell, or makes unusual noise,
immediately remove the batteries and stop using it.
CAUTION
Do not place or store in the following areas:
• Areas exposed to direct sunlight
• Areas subject to high temperatures such as near fire or heating equipment
• Areas exposed to static electricity
• Areas exposed to strong magnetic fields
• Areas exposed to dampness
• Areas subject to condensation or wet areas
• Areas exposed to excessive vibration
• Areas exposed to excessive smoke, dust or dirt.
CAUTION
Other Precautions
• Use the unit in the specified operating environment. Do not use it for any purpose other than for which it was
designed.
• Condensation may occur inside the case when a unit is moved from one environment to another where there is
a great difference in temperature. Be careful to avoid condensation.
• Contact with oil may cause cracks to appear in the casing of the unit. When using this unit in environments
where such oils are present, please insure that it is protected from contact through use of a polyethylene bag or
other means.
• Do not insert any foreign objects into any of the units' jacks.
• The following may cause water or foreign objects to enter the unit:
· Closing the case with dirt, dust, or hair on the rubber packing or between the unit and rubber packing
· Scratches on the rubber packing
· Involving a significant temperature change (especially from high to low) while the unit is wet
• If the unit gets dirty, wipe it with a clean cloth.
• Please note that this manual has been written based on the presupposition that details about set-up of any
necessary equipment to enable network connection have already been taken care of by the user and that
connection has been confirmed as workable. T&D Corporation shall not be responsible for any damages which
a contractor, a user or a third party may suffer, whether direct or indirect, due to the inability to communicate or
use communication devices.
CAUTION
Installation Precautions for Wireless Communication Devices
When installing wireless communication devices take special care in selecting locations so as to ensure
proper communication. Note that even after a successful installation, due to changes in environmental
conditions, communication errors may occur when restarting the system.
As far as possible, try to keep wireless communication devices away from metals and set them up in high
unobstructed positions.
• Please take note that in many instances, walls, floors, stairs, fences and desks will contain metals. In order to
carry out communication between indoor and outdoor units, please locate indoor units near a window so that
radio waves can be easily transmitted.
• Please install the unit more than 30 cm away from walls or boards containing metal.
• If the unit is placed in a metal container such as a freezer or refrigerator, the possible wireless communication
range will be shortened. In most cases radio waves are transmitted via doors and door openings so place the
unit as near to doors as possible.
• As far as possible, keep the unit away from noise-emitting sources.
• Equipment such as some industrial instruments, electronic devices or fluorescent lamps generate noise. Please
place the unit more than 1 meter away from such devices.
• Please place the unit more than 1 meter away from computers and other devices which emit noise.
• Keep all wires as far away from wireless communication devices as possible. Please be careful about placing
near any wiring or cables such as power supply cables, telephone wires or LAN cables.
• Objects which contain lots of water, such as plants or soil, absorb radio waves. We highly recommend that such
materials should not be placed between or near wireless communication units. When measuring temperature in
a greenhouse it has been reported that as plants grew, communication errors also increased.
• Do not place the unit directly on the ground.
• Do not place units which are using the same communication frequency channel in the same area. If the same
channel is used for multiple units not only will more communication errors occur, but battery life will also be
shortened.