background image

• If there is a possibility that units with the same frequency channel will be in wireless communication at the 

same time, please make sure to make changes to the frequency channels so they are not the same.

Important Notices and Disclaimers

In order to properly use this product, please carefully read all documents that accompany the product 

before using. T&D Corporation accepts no responsibility for any malfunction of and/or trouble with this 

product or with your computer that is caused by the improper handling of this product and will deem 

such trouble or malfunction as falling outside the conditions for free repair outlined in the attached 

warranty.

•  All rights of the attached documents belong to T&D Corporation. It is prohibited to use, duplicate and/or ar-

range a part or whole of the attached documents without the permission of T&D Corporation.

•  Microsoft and Windows are registered trademarks of Microsoft Corporation in the United States and/or other 

countries.

•  Windows Vista is either a registered trademark or trademark of Microsoft Corporation in the United States and/

or other countries.

•  All registered trademarks, company names, product names and logos mentioned herein or for products being 

used are the property or registered property of T&D Corporation or of their respective owners. 

•  Specifications, design and other contents outlined in the attached documents are subject to change without 

notice.

•  Please follow the safety precautions outlined in the attached documents carefully. We cannot guarantee nor 

are we responsible for safety if this product is used in any manner other than was intended.

•  On-screen messages in the attached documents may vary slightly from the actual messages.

•  Please notify the shop where you purchased this product or T&D Corporation of any mistakes, errors or unclear 

explanations in the attached documents. 

T&D Corporation accepts no responsibility for any damage or loss of income caused by the use of our product.

•  Accompanying documents cannot be reissued, so please keep them in a safe place.

•  Please read the warranty and provisions for free repair carefully.

Compliance Information

CE Statement

This device complies with technical specifications required under EN 301 489 

(with battery and AC Adaptor), EN 300-220, and EN 60950-1.

Important Notices

Wireless products cannot be used in countries other than where those products have been approved for 

use, according to that country's wireless regulations.
T&D Corporation shall in no manner whatsoever take responsibility for the usage of these products, nor 

be liable in any manner for legal consequences stemming from the usage of these wireless products in 

unapproved areas.

For product information or questions contact us at: 

817-1 Shimadachi Matsumoto, Nagano 390-0852 JAPAN
Fax: +81-263-40-3152     E-mail: [email protected]

http://www.tandd.com/

We have opened an English Website for your convenience. Here you can find information about our 

company, news, products, upcoming events, software and Introductory Manual downloads, as well as, 

ther support. Please stop by and see what we have to offer.

Specifications

Unit type

RTR

-501 / RTR-501L

RTR

-502 / RTR-502L

RTR

-503 / RTR-503L

RTR

-507 / RTR-507L

Measurement Channels

Temperature 1ch ( Internal )

Temperature 1ch ( External )

Temperature 1ch, Humidity 1ch  

( External )

1 Temperature Channel

( External )

1 Humidity Channel

( External )

Sensor

Thermistor

Thermistor

Thermistor

Polymer Resistance

Platinum Resistance

Electrostatic Capacitance

Measurement Units

°C, °F

°C, °F

°C, °F

%RH

°C, °F

%RH

Measurement Range

-40 to 80°C

-60 to 155°C

0 to 55 °C

10 to 95 %RH

-30 to 80 °C

0 to 99 %RH

Accuracy

Avg.±0.5 °C

Avg.±0. 3°C 

-20 to 80 °C ]

Avg.±0.5 °C 

-40 to -20 °C / 80 to 11 0 °C ]

Avg.±1.0 °C 

-60 to -40 °C / 110 to 155 °C ]

Avg.±0.3 °C

±5 %RH  

[ at 25 °C, 50 %RH ]

±0.3°C [ at 0 to 50 °C ]

±0.5°C [ at all other 

temperatures ]

±2.5 %RH [ at 25 °C, 10 to 85 %RH]

±4.0 %RH [ at 25 °C, 0 to 10 % or 85 

to 99 %RH ]

At temperatures other than 25 °C and  

≥ 0 °C, add ±0.1 %RH per degree of 

difference from 25.

Humidity Hysteresis: ±1.5 %RH or 

lower (*1)

Measurement Resolution

0.1°C

0.1°C

0.1°C

1 %RH

0.1 °C

0.1 %RH

Responsiveness

Thermal Time Constant:  

Approx. 15 min. 

Approx. 25 min. ( L Type ) 

Response Time ( 90% ):  

Approx. 35 min. 

Approx. 47 min. ( L Type )

Thermal Time Constant:  

Approx. 30 sec. ( in air ) 

Approx. 4 sec. ( in agitated water ) 

Response Time ( 90% ):  

Approx. 80 sec. ( in air ) 

Approx. 7 sec. ( in agitated water )

Response Time ( 90% ): 

Approx. 7 min.

Response Time ( 90% ):

Approx. 7 min.

Response Time (90%):

Approx. 20 sec.

Logging Capacity

16,000 readings

8,000 data sets ( One data set consists of readings for multiple channels. )

Recording Interval

Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min.

Recording Mode (*2)

Endless ( Overwrite oldest data when capacity is full ) or One Time ( Stop recording when capacity is full )

Communication Interfaces

- Wireless Communication ( Short Range Radio Communication )

ETSI EN 300 220 ( Frequency Range: 869.7 to 870 MHz, RF Power: 5 mW )

- Optical Communication ( proprietary protocol )

Wireless Transmission Range

Approx. 150 meters (500 ft) if direct and unobstructed

Power

Lithium Battery: LS14250 (*3) x 1    L Type: Large Capacity Battery Adaptor Kit ( RTR

-500B1 ) (*4) 

External Power Adaptor Kit ( RTR

-500A2: sold separately ) (*5) 

Battery Life (*6)

About 10 months

L Type: About 4 years

Dimensions

H 62 mm x W 47 mm x D 19 mm 

L type:  H 62 mm x W 47 mm x D 46.5 mm

( excluding protrusions and sensor )

Antenna length: 24 mm

Weight

Approx. 56 g

L Type: approx. 109 g

( including battery / excluding sensor )

Operating Environment

-40 to 80°C

-30 to 80°C during wireless communication )

-40 to 80°C 

-10 to 80°C during wireless communication ) (*7)

Waterproof Capacity

IP67: Immersion proof

IP64: Splash proof 

 (rated for use in daily life) (*8)

IP64: Splash proof  ( rated for use in daily life ) (*8)  

Note: Sensor is not water resistant.

Compatible Base Units

RTR

-500, RTR-500NW/500AW, RTR-500DC, RTR-500GSM

RTR

-500, RTR-500NW/500AW, RTR-500DC

*1: When used in environments where temperature and humidity are over the values of 50°C 75%, 60°C 50%, 70°C 35%, and 80°C 25%, sensor hysteresis may fluctuate by values greater than ±1.5%RH. 

Under certain circumstances, it may take some time to return to normal measurement capability.

*2: Only "Endless" is available when using RTR-500W for Windows or RTR-500GSM for Windows.
*3: The included lithium battery ( LS14250 ) is not sold in stores. Please purchase the optional battery set ( TR-11P2 ) for replacement. 
*4: When using RTR-500B1 it is necessary to purchase Lithium Battery ( LS26500 ). For details, contact your local authorized distributor.
*5: RTR-500A2 should not be used with the RTR-501, as it will cause the RTR-501 to display a higher than actual temperature reading of up to 3°C. 
*6: Battery life varies depending upon the ambient temperature in which it is used, the recording interval, the frequency of communication, and the battery performance. All estimates are based on operations 

carried out with a new battery and are in no way a guarantee of actual battery life.

*7: When wireless communication is performed in an environment below -10°C, measurement may fail or may not be accurate.
*8: This is the waterproof capacity of the data logger with the sensor connected. 
The specifications listed above are subject to change without notice. 

Cautions about using the Included Sensors

Temperature Sensor: TR-5106

 

Waterproof

Materials:   Thermistor   Fluoropolymer-coated Electrical Wire 

• Do not bend or press the last 5 cm to the tip of the sensor, as this 

may damage it.

• If the fluoropolymer-coated section of the sensor and/or the 

cable has a defect or tear, the waterproof capacity will be lost. 

Inspect it before operation.

• Insert the sensor tip to at least 5 cm or more to obtain on 

accurate temperature measurement.

• Only use the sensor within the sensor temperature durability 

range ( -70 to 180˚C ).

Temperature/Humidity Sensor: TR-3310

 

Materials:   Temp/Humidity Sensor   Polypropylene Resin   Vinyl Chloride 

Coated Electrical Wire 

• This sensor is not water resistant. Do not use it in places subject 

to condensation or dampness. If the sensor gets wet, immediately 

remove the sensor from the unit and wipe it with a clean cloth as 

soon as possible. Then allow the sensor to dry in normal room 

temperature before using it again.

• Do not use the sensor in places subject to corrosive gases or 

organic solvents.

• Do not expose the sensor to a strong impact. This may adversely 

affect measurement accuracy and cause damage or malfunction.

• Continued use may cause a decrease in the sensor's accuracy 

and sensitivity even under normal operational conditions. Periodic 

calibration may be required.

• When the sensor is not to be used for a long period of time, store it 

at normal temperature and humidity.

High Precision Temperature/Humidity Sensor: 
HHB-3101

Materials:   Temp/Humidity Sensor   Polycarbonate    Vinyl Chloride Coated 

Electrical Wire 

• This sensor is not water resistant. Do not use it in places subject to 

condensation or dampness. If the sensor gets wet, immediately remove the 

sensor from the unit and wipe it with a clean cloth as soon as possible. Then 

allow the sensor to dry in normal room temperature before using it again.

• Do not use the sensor in places subject to dust, corrosive gases or organic 

solvents.

• Do not expose the sensor to a strong impact. It may adversely affect 

measurement accuracy and cause damage or malfunction.

• Continued use may cause a decrease in the sensor’s accuracy and 

sensitivity by about 1% per year even under normal operational conditions.

• When used in environments where temperature and humidity are over 

the values of 50˚C 75%, 60˚C 50%, 70˚C 35%, and 80˚C 25%, sensor 

hysteresis may fluctuate by values greater than ±1.5%RH. Under certain 

circumstances, it may take some time to return to normal measurement 

capability.

• When the sensor is not to be used for a long period of time, please store it at 

normal temperature and humidity.

Explanation of Symbols

<Warning Symbols>

 

 DANGER

These entries are actions that, if taken, may cause serious personal 

physical damage or death.

 

 CAUTION

These entries are actions that if taken may lead to physical injury or 

damage to persons or things.

<Picture Symbols>

Denotes an important 

warning or caution.

Denotes a 

forbidden action.

Denotes an action that 

should be carried out.

 DANGER

To Prevent Serious Accidents

Do not disassemble, repair or modify the unit and accessories.

Do not use the unit in any environment that is exposed to chemicals and harmful gases. 

Doing so may cause corrosion and/or other danger to the unit. Also, coming in contact with 

hazardous substances may cause bodily harm to the user or people nearby.

If water or a foreign object enters the case, immediately remove batteries and stop using it.

Do not insert or replace batteries with wet hands.

This product has been designed for private and/or industrial use only. It should not be used in 

situations where strict safety precautions are necessary such as with medical equipment, or 

in systems directly or indirectly connected with human life or well-being.

Do not drop or expose the unit to a strong impact.

Do not cut or process the sensor cables. Also, do not twist, pull on or swing any of the 

cables.

To prevent damage to the unit from static electricity, remove static electricity from your body 

by touching metal around you (such as a door knob and window frame) before touching the 

unit.
Please be careful not to touch the unit during or after use in overly hot or cold environments. 

It may cause burns or frostbite.

Place and store the unit and accessories out of the reach of children.

Further, T&D is not responsible for any damage, malfunction or trouble, whether direct or 

indirect, caused by the use of our products.

Do not use any power or sensors other than those specified by T&D Corporation.

If the unit produces heat, emits smoke or a strange smell, or makes unusual noise, 

immediately remove the batteries and stop using it.

 CAUTION

Do not place or store in the following areas:

• Areas exposed to direct sunlight

• Areas subject to high temperatures such as near fire or heating equipment

• Areas exposed to static electricity

• Areas exposed to strong magnetic fields

• Areas exposed to dampness

• Areas subject to condensation or wet areas

• Areas exposed to excessive vibration

• Areas exposed to excessive smoke, dust or dirt.

 CAUTION

Other Precautions

• Use the unit in the specified operating environment. Do not use it for any purpose other than for which it was 

designed.

• Condensation may occur inside the case when a unit is moved from one environment to another where there is 

a great difference in temperature. Be careful to avoid condensation.

• Contact with oil may cause cracks to appear in the casing of the unit. When using this unit in environments 

where such oils are present, please insure that it is protected from contact through use of a polyethylene bag or 

other means.

• Do not insert any foreign objects into any of the units' jacks.

• The following may cause water or foreign objects to enter the unit:

· Closing the case with dirt, dust, or hair on the rubber packing or between the unit and rubber packing
· Scratches on the rubber packing
· Involving a significant temperature change (especially from high to low) while the unit is wet

• If the unit gets dirty, wipe it with a clean cloth.

• Please note that this manual has been written based on the presupposition that details about set-up of any 

necessary equipment to enable network connection have already been taken care of by the user and that 

connection has been confirmed as workable. T&D Corporation shall not be responsible for any damages which 

a contractor, a user or a third party may suffer, whether direct or indirect, due to the inability to communicate or 

use communication devices.

 CAUTION

Installation Precautions for Wireless Communication Devices

When installing wireless communication devices take special care in selecting locations so as to ensure 

proper communication. Note that even after a successful installation, due to changes in environmental 

conditions, communication errors may occur when restarting the system.
As far as possible, try to keep wireless communication devices away from metals and set them up in high 

unobstructed positions.

• Please take note that in many instances, walls, floors, stairs, fences and desks will contain metals. In order to 

carry out communication between indoor and outdoor units, please locate indoor units near a window so that 

radio waves can be easily transmitted. 

• Please install the unit more than 30 cm away from walls or boards containing metal.

• If the unit is placed in a metal container such as a freezer or refrigerator, the possible wireless communication 

range will be shortened. In most cases radio waves are transmitted via doors and door openings so place the 

unit as near to doors as possible.

• As far as possible, keep the unit away from noise-emitting sources.

• Equipment such as some industrial instruments, electronic devices or fluorescent lamps generate noise. Please 

place the unit more than 1 meter away from such devices. 

• Please place the unit more than 1 meter away from computers and other devices which emit noise.

• Keep all wires as far away from wireless communication devices as possible. Please be careful about placing 

near any wiring or cables such as power supply cables, telephone wires or LAN cables.

• Objects which contain lots of water, such as plants or soil, absorb radio waves. We highly recommend that such 

materials should not be placed between or near wireless communication units. When measuring temperature in 

a greenhouse it has been reported that as plants grew, communication errors also increased.

• Do not place the unit directly on the ground.

• Do not place units which are using the same communication frequency channel in the same area. If the same 

channel is used for multiple units not only will more communication errors occur, but battery life will also be 

shortened.

Summary of Contents for RTR-501

Page 1: ...Included RTR 503 With External Temperature Humidity Sensor TR 3310 Included RTR 507 With High Precision Temperature Humidity Sensor HHB 3101 Included Common Accessories Lithium Battery LS14250 Strap User s Manual Warranty Included T D Corporation Copyright T D Corporation All rights reserved 2015 03 16504590029 5th Edition Printed on recycled paper ...

Page 2: ... Unit connected to your PC RTR 501 RTR 502 RTR 503 and RTR 507 are Remote Units They require Base Units to carry out wireless communication For details about available operations via wireless communication or how to make recording settings see the Introductory Manual included with the Base Unit or see the application s Help Please set up the Base Unit first before the Remote Unit Part Names RTR 50...

Page 3: ... Recording in progress BLINKING Waiting for programmed start OFF Recording stopped Battery Warning Mark When it is time for the battery to be replaced this mark will appear Units of Measurement Recording Mode ONETIME When the recording mode is set to One Time Mode Stop recording when capacity is full this mark will appear Measurement and Message Display Area Measurements or operational messages ar...

Page 4: ... hours About 166 days and 16 hours About 1 year and 10 months RTR 503 507 About 2 hours and 13 minutes About 2 days and 18 hours About 83 days and 8 hours About 11 months Check This will be displayed under the following conditions The first time a battery was inserted after purchase When the battery is replaced after having been taken out for a long period Wireless Transmission This will appear wh...

Page 5: ...h a new one as soon as possible 1 When it is time for the battery to be replaced a battery warning mark will appear RTR 501 502 503 RTR 507 2 If you do not change the battery and continue using the RTR 501 RTR 502 or RTR 503 the display will alternately flash bAtt and the current temperature The RTR 507 will alternately flash bAtt and and then stop the measurement In this condition recording will ...

Page 6: ...w 0 C or above 60 C Exposing the CR2 to continuous vibration such as in transportation When using a CR2 lithium battery the tube is not necessary To maintain waterproof capacity when changing batteries also change the rubber packing and the drying agent silica gel When using a CR2 lithium battery please purchase the optional Maintenance Set TR 00P1 to replace the rubber packing and silica gel Abou...

Page 7: ...y LS14250 3 x 1 L Type Large Capacity Battery Adaptor Kit RTR 500B1 4 External Power Adaptor Kit RTR 500A2 sold separately 5 Battery Life 6 About 10 months L Type About 4 years Dimensions H 62 mm x W 47 mm x D 19 mm L type H 62 mm x W 47 mm x D 46 5 mm excluding protrusions and sensor Antenna length 24 mm Weight Approx 56 g L Type approx 109 g including battery excluding sensor Operating Environme...

Page 8: ...or Polypropylene Resin Vinyl Chloride Coated Electrical Wire This sensor is not water resistant Do not use it in places subject to condensation or dampness If the sensor gets wet immediately remove the sensor from the unit and wipe it with a clean cloth as soon as possible Then allow the sensor to dry in normal room temperature before using it again Do not use the sensor in places subject to corro...

Page 9: ...corrosive gases or organic solvents Do not expose the sensor to a strong impact It may adversely affect measurement accuracy and cause damage or malfunction Continued use may cause a decrease in the sensor s accuracy and sensitivity by about 1 per year even under normal operational conditions When used in environments where temperature and humidity are over the values of 50 C 75 60 C 50 70 C 35 an...

Page 10: ...m contact through use of a polyethylene bag or other means Do not insert any foreign objects into any of the units jacks The following may cause water or foreign objects to enter the unit Closing the case with dirt dust or hair on the rubber packing or between the unit and rubber packing Scratches on the rubber packing Involving a significant temperature change especially from high to low while th...

Page 11: ...ety precautions outlined in the attached documents carefully We cannot guarantee nor are we responsible for safety if this product is used in any manner other than was intended On screen messages in the attached documents may vary slightly from the actual messages Please notify the shop where you purchased this product or T D Corporation of any mistakes errors or unclear explanations in the attach...