![TANDBERG SDLT600 User Reference Manual Download Page 25](http://html2.mh-extra.com/html/tandberg/sdlt600/sdlt600_user-reference-manual_4989978025.webp)
E1 | Specifications
Physical Specifications
The following table lists environmental operating limits and
accuracy for the SDLT 600 tape drive.
Data Integrity
Error Type
Frequency
Detected, Recoverable
(ECC) Read
< 1 error in 10
6
bytes read
Detected, Unrecoverable
Read
< 1 error in 10
17
bits read
Undetected Read
< 1 error in 10
27
bits read
Rewrite of Data
< 1 per 10
6
bytes written
Temperature
Operating
10 °C to 40 °C (50 °F to 104 °F)
Storage
-40 °C to 66 °C (-40 °F to 150 °F)
Humidity
Operating
20% to 80% non-condensing
Storage
10% to 95% non-condensing
Safety Certifications
Meets UL 60950, GS mark, and EN60950/IEC 950 standards
(EN60825-1: Information Technology Equipment)
Air Flow
10.4 CFM minimum with 0.09 in H
2
O pressure drop
Note:
Allow at least 100 mm of unobstructed space behind the
tape drive for proper air flow.
Electrical Rating (numbers describe the Ultra 160 model)
Tabletop
85 to 264 VAC, 61 W typical,
100 W (power supply rating)
maximum, 47 to 63 Hz
Internal
+5V, 4.9 A RMS, 6.2 A Peak,
typical
+12V, 0.7 A RMS, 2.7 A Peak,
typical