Operating the Equipment Locally — Advanced Menu
Reference Guide: evolution 5000 E5780 and E5782 Encoder
Page 4-19
ST.RE.E10135.4
4.4.6
Digital Programme Insertion (DPI) Menu
The Digital Programme Insertion (DPI) Menu is only available when the M2/ESO2/DPI Licence
key is purchased and is selected from the System Menu. The available options are described
in Section 4.12.
DPI can be initiated via the M2/EOM2/GPI card or by the DVS 525 protocol.
Path: Summary Screen [More]> Setup> System> DPI Insertion
4.4.7 Advanced
Menu
The
Advanced Menu
is selected from the
System Menu
by pressing the Advanced softkey.
This menu provides options for the advanced parameters of the Encoder. See Figure 4.4 for
the
Advanced
Menu
structure and Table 4.7 for the option descriptions.
Path: Summary Screen [More]> Setup> System> Advanced
Table 4.7: Advanced Menu Options
Selected Item
Options
Description
Setup Password:
.
Only available from the front panel. If the Setup Password option is set to
On then a password is required to change any parameters.
CAUTION…
Only set this option if you know the password!
The default is: 0123456789
Current Password:
Enter the current password.
Only available from the front panel
For forgotten passwords, contact Customer Services.
Display Errors:
Enable or disable the display of
error or alarm messages on the
front panel.
Off-line
O/P Status
On-line
Switches the output.
MEM/nCC
Control of the video/audio delay (lip sync) is via the MEM or nCompass
Control.
Local
Control of the video/audio delay (lip sync) is within the Encoder.
External (SNMP)
Control of the video/audio delay (lip sync) is via the SNMP protocol.
System Control:
Sets the type of system control
specified in the SI.
If the control equipment is a TT7000 System Manager, ensure that the Auto Lip Sync option is turned
on (see Auto Lip Sync in Table 4.18: Audio A/B Option Descriptions. The TT7000 does not have a lip
sync function therefore the Encoder has to provide this.
Raise Alarm
An error message is displayed if a PID error is found.
Action On PID Error:
Auto Correct
If a PID error is found it is automatically corrected.
Wait for Initialisation
No SNMP reply during initialisation.
SNMP Control:
This option enables the SNMP
Control to be set.
From Power On
Reply as modules start to appear.
Very Light
Light
Medium
Dark
Display Contrast:
Sets the contrast ratio of the LCD
display.
Very Dark
As the key is pressed the display changes.
If the background is set to very dark or very light, the text may not be visible. In
this instance, view the display at an acute angle, this should enable the text to
be seen enough to change the contrast.