4
SCSI Cable
Host
Last SCSI Device
Internal Terminator Connector
SCSI-bus
10 cm
Figure 4
SCSI cable
•
Internal SCSI-LVD/SE-cable with 5 connectors (Ordering no. 43 20 51)
•
Internal, removable SCSI-LVD/SE-terminator
(Ordering no. 43 20 53)
•
External, removable SCSI-LVD/SE-terminator
(Ordering no. 43 26 17)
•
External SCSI 68HD/VHDCI 320MBs-cable
(Ordering no. 43 32 64)
Termination
The SCSI-bus cable must be terminated in both ends according to SCSI
specifications. If the tape drive is the last device on the bus, the bus must be
terminated within 10 cm of the tape drive connection.
Tandberg 220/420LTO has a combined SCSI-LVD/SE interface embedded. The
PC-98 Specification specifies that the termination of the SCSI-bus system is a part
of the SCSI-cable and not a part of the SCSI-device.
As a result, termination cannot be turned on or off directly on the tape drive itself.
For internal devices, a SCSI-cable with an integrated terminator or a separate
terminator applied to the end connector of the cable, 10 cm from the last device,
must be used.
External devices must be terminated with an external terminator on the last device
on the SCSI-bus.
Software Installation
For Software Application support and software drivers, please see
www.tandberg.com. Then select SUPPORT and Select Product.
For installation of Backup Application software, refer to the software vendor’s
software application user guide supplied with the software or on the software
vendor’s web.