StorageLoader 2U LTO

  

Quick Start Guide

Page 7 of 8

Troubleshooting Tips

If the library did not power 
on as described

• Is the power cord inserted correctly and is the power switch on (press the 

I

 on the   

 

  back of the unit)?
• Did you remove the shipping key?

If the library displays an 
error on the front panel

Refer to the 

Product Manual 

for a list of error messages and corrective actions. 

If the Diagnostic tools 
(LIBTool and LTOTool) are 
not communicating with the 
library

• 

Host adapter card installation—

Make sure that you installed your host adapter card 

correctly, that the card is securely seated, and that the appropriate drivers for the 
adapter are installed. Refer to the documentation that came with your controller for 
installation instructions.

• 

SCSI ID*—

If additional SCSI devices are attached to the same SCSI bus as the library, 

you may need to change the SCSI IDs of the tape drive(s) in the library.**

• 

Termination*—

Make sure the SCSI bus is properly terminated (see step 3).**

 

Make sure the terminator is securely connected.

• 

SCSI connections*—

Make sure that all SCSI cables are securely connected.

• Fibre Channel connections—

Make sure that the GBICs and cables used to connect 

the tape drives in the library to the Fibre Channel loop are compatible. Make sure that 
the FC cables are firmly connected to the tape drives and the FC hub or switch. 

• 

SCSI controller type*—

Make sure that the SCSI controller is an LVD controller. 

DO NOT connect the tape drive(s) in the library to a single-ended controller, a RAID 
controller, or an HVD controller.

• 

LVD SCSI devices*—

The tape drives in the library are LVD (low-voltage differential) 

device(s), and all other devices on the SCSI bus must also be LVD (controller card, 
terminator, and all other devices on the bus).

If your backup software is 
not communicating with the 
library

• 

Bus configuration and cables—

Refer to the installation instructions (and tips above). 

Improper bus configuration or bad cables often cause these issues:

 

 - Devices not being seen in the operating system

    - Losing communication with a tape drive during backup
    - Event ID 9 or 11 errors in Windows operating systems
    - Unexpected bus resets 
    - Intermittent or unexpected “I/O” errors
    - Parity errors

• 

Software compatibility—

Make sure that your library and tape drive are compatible with 

the backup software you plan to use. Check www.tandbergdata.com.

• Control mode—

Use Random mode (the default) with an application that controls the 

library. Use sequential mode only if your backup application will not control the library.**

• Tape Drive Configuration—

Make sure that the Drive Configuration (Drive/Drive 

Configuration) matches the tape drive(s) installed.** 

• 

Driver installation—

Some applications provide their own drivers, some do not, 

and some require installation of the Tandberg Data provided drivers. Refer to the 
documentation for your backup application and Tandberg Data Knowledge base item 
#2003 (www.tandbergdata.com) for more information.

If your library displays a 

Clean Tape Drive

 message 

on the front panel 

Use one of the following options to clean the tape drive: 
• Instruct your backup software to issue a Clean the Tape Drive command. Refer to 

 

  the software documentation and the library 

Product Manual 

for instructions. 

• Use the library’s Autoclean option.** 
• Manually install a cleaning cartridge when the tape drive requires cleaning.**

* All references to SCSI are for the SCSI library only.
** Refer to the Library’s Product Manual for instructions or additional information.

Summary of Contents for StorageLoader 2U LTO

Page 1: ...FC cable Power cord for use outside Europe If you plan to use the library outside Europe you must supply your own power cord see the Product Manual at www tandbergdata com for information about an In...

Page 2: ...off position and that the power cord is disconnected from the library and the outlet WARNUNG Vor der Ausf hrung von Installations oder Wartungsarbeiten ist darauf zu achten da der Library Netzschalte...

Page 3: ...he library by pressing the power switch on the back of the unit press the I When you apply power with the shipping lock installed the library displays a message and ejects both left magazines 2 Pull t...

Page 4: ...the right approximately 1 inch 2 5cm Important If you do not remove rotate and lift the shipping lock as described in steps b and c you can catch and damage cables inside the library and render it us...

Page 5: ...brary s cartridge inventory Move tapes into and out of the tape drive 3 Use LTOTool to a Detect the tape drive b Perform a Read Write test Note The readme files that accompany LibTool and LTOTool prov...

Page 6: ...l number code level and SCSI ID and LUN or WWNN Library Settings Library Maintenance Operation Mode Library Status Mag 224 Main Menu vsd Password Ethernet DHCP4 IP Address Subnet Mask Gateway MAC Addr...

Page 7: ...s and all other devices on the SCSI bus must also be LVD controller card terminator and all other devices on the bus If your backup software is not communicating with the library Bus configuration and...

Page 8: ...ion Additional Information 1016989A REGISTER YOUR LIBRARY AT www tandbergdata com Copyright 2007 Tandberg Data Exabyte the Exabyte logo EZ17 M2 VXA and VXAtape are registered trademarks ExaBotics Mamm...

Reviews: