Tandberg Data STORAGE LIBRARY T40 Quick Installation Manual Download Page 2

2  

Quick Installation Steps 

For more information and complete step-by-step instructions, see 
Tandberg StorageLibrary

TM

 T40 Installation and User Guide.  

 

Caution 

The Tandberg StorageLibrary

TM

 T40 could be lifted by 

one person if drives, power supply, and magazines are 
removed. However, for absolute safety, it is 
recommended that two people lift the Tandberg 
StorageLibrary

TM

 T40. Full library weight = 38 kg / 84 lbs 

(2 FH drives). Empty library weight = 23.6 kg / 52 lbs 
(does not include drives, magazines or power supply). 

 

Caution 

The transport locking screws must be removed before 
the Tandberg StorageLibrary

TM

 T40 can operate 

normally.  

When following the steps below, see corresponding numbers on the 
illustrations. 

1  If the library is a rack mount version, power on the unit to remove 

the locking screws and install the rack mount ears. Install the 
library in a rack.  If the library is a tabletop version, keep the 
locking screws mounted and install the tabletop kit. For 
instructions, see Tandberg StorageLibrary

TM

 T40 Installation and 

User Guide

2  If your library includes SCSI tape drives connect the SCSI cables 

to the connectors on the drive sled. See the Installation and User 
Guide for installation requirements when using more than 2 SCSI 
drives. 

a.  Connect a jumper cable between the top SCSI connector of 

the bottom drive and the bottom SCSI connector of the drive 
above it. Repeat this step for all drives on the SCSI bus. 
Secure the cable with the thumbscrews on the connectors. 

b.  Terminate the last device on the SCSI bus with the 

appropriate SCSI terminator. 

c.  Connect a cable between the first drive on the SCSI bus and 

the host. Note that there are limitations to the length of the 
SCSI cable. In a typical installation, the cable length should 
not exceed 9 meters / 30 feet. 