2
Quick Installation Steps
For more information and complete step-by-step instructions, see
Tandberg StorageLibrary
TM
T40 Installation and User Guide.
Caution
The Tandberg StorageLibrary
TM
T40 could be lifted by
one person if drives, power supply, and magazines are
removed. However, for absolute safety, it is
recommended that two people lift the Tandberg
StorageLibrary
TM
T40. Full library weight = 38 kg / 84 lbs
(2 FH drives). Empty library weight = 23.6 kg / 52 lbs
(does not include drives, magazines or power supply).
Caution
The transport locking screws must be removed before
the Tandberg StorageLibrary
TM
T40 can operate
normally.
When following the steps below, see corresponding numbers on the
illustrations.
1 If the library is a rack mount version, power on the unit to remove
the locking screws and install the rack mount ears. Install the
library in a rack. If the library is a tabletop version, keep the
locking screws mounted and install the tabletop kit. For
instructions, see Tandberg StorageLibrary
TM
T40 Installation and
User Guide.
2 If your library includes SCSI tape drives connect the SCSI cables
to the connectors on the drive sled. See the Installation and User
Guide for installation requirements when using more than 2 SCSI
drives.
a. Connect a jumper cable between the top SCSI connector of
the bottom drive and the bottom SCSI connector of the drive
above it. Repeat this step for all drives on the SCSI bus.
Secure the cable with the thumbscrews on the connectors.
b. Terminate the last device on the SCSI bus with the
appropriate SCSI terminator.
c. Connect a cable between the first drive on the SCSI bus and
the host. Note that there are limitations to the length of the
SCSI cable. In a typical installation, the cable length should
not exceed 9 meters / 30 feet.