Tandberg Data FC420 Bridge Option User’s Guide
Document T6423053-01, Ver. 1, Rel. 0
November 2002
Setting SCSI IDs
7
Figure 4
shows a six-drive library utilizing a two-drive per port
cabling scheme.
Figure 4 Two-Drives-Per-
FC420-Port Cabling
Setting SCSI IDs
0
Use the information in
table 1
to set the SCSI device addressing (SCSI
IDs) for the library.
Table 1 SCSI ID Settings
Note:
To increase the bandwidth available to each tape drive,
install additional FC420 Fibre bridges and use the cabling
configuration shown in
figure 3
.
Device
SCSI ID
Device
SCSI ID
SCSI Controller
0
Drive 3
4
Drive 0
1
Drive 4
5
Drive 1
2
Drive 5
6
Drive 2
3
Drive 2
Drive 1
Drive 4
Drive 3
Drive 6
Drive 5
Slot for FC420
FC420
FC420
SCSI controller
SCSI
SCSI
SCSI
SCSI
2-GB SAN
Fibre
Primary
electronics
module
Auxiliary
electronics
module
M2500
SCSI
SCSI
Fibre
SCSI
Terminator