Tandberg LTO HH Installation and User Manual
35
8 App. A. LED-Indicator Behavior
8.1 LED-behavior During Normal Operation
Drive State
1
READY LED
(Green left)
ACTIVITY
LED
(Green)
CLEAN LED
(Amber)
FAULT LED
(Amber right)
LED-test.
The LEDs are turned ON in sequence
Power-On Self-Test
Starts in parallel with the LED-test .
ON
Flashing in about
12 sec
ON
After 12 sec:
Flashing during
cartridge load
ON
OFF
ON
OFF
LED-test.
The LEDs are turned ON one-by-one.
Power-On Self-Test starts in parallel
with the LED-test
2
.
ON
ON
ON
ON
Diagnostic Activity / POST
4
Flashing
OFF
OFF
OFF
Aborting Diagnostic Test
Flashing
ON / OFF /
Flashing
ON
3
/ OFF
Flashing
Cartridge not loaded.
OFF
OFF
ON
3
/ OFF
OFF
Cartridge loaded, no activity
ON
OFF
ON
3
/ OFF
OFF
Cartridge loaded, activity
ON
Flashing
ON
3
/ OFF
OFF
Cleaning
OFF
Flashing
ON
OFF
Cartridge loading or unloading
OFF
Flashing
ON
3
/ OFF
OFF
Unrecoverable drive failure
ON / OFF
OFF
ON
3
/ OFF
Flashing
5
Firmware download
in progress
Flashing
OFF
ON
3
/ OFF
OFF
Firmware update
in progress
Flashing
Flashing
ON
3
/ OFF
OFF
Firmware download failure
6
Flashing
Flashing
ON
3
/ OFF
Flashing
5
Over temperature
7
OFF
OFF
ON
3
/ OFF
ON
Aborting Diagnostic Test
Flashing
ON / OFF
ON
3
/ OFF
Flashing
Media Error (wrong, write protected or
harmed media)
OFF
Flashing
ON
3
/ OFF
Flashing