                                           TX7211 Addressable Sounder Circuit Module 

   Installation & Operation Manual 

                                                                                                                                4050100453-Rev1.1-1217                                                                        

 

 

    TANDA UK   

                                                                                                                                           

Specifications are subject to change w ithout prior notice 

      

 

2 Installation   

 

2.1 Installation Preparation 

This Addressable Sounder Circuit Module Unit must be installed, commissioned and maintained by a 
qualified or factory trained service personnel. The installation must be installed in compliance with all 
local codes having a jurisdiction in your area or BS 5839 Part 1 and EN54. 

Tand  products has available  range of Addressable Sounder Circuit  Module   Unit, each Unit  is 
designed for specific application, it is essential to consider the requirement of both sides of the Unit 

to avoid malfunction and typical fault scenario. The main caution is to ensure that the voltage rating 
of the equipment and Unit are compatible.  

2.2 Installation and Wiring 

1.

 

Mount the Addressable Sounder Circuit Module  Unit  base  on standard one [1] gang 

electrical back box.  Follow the arrow mark for the correct position. Do not over-tighten the 

screws otherwise the base will twist. Use two M4 standard screws. 

2.

 

Connect the wire in terminal according to the requirement as shown in Figure [2]. Verify the 

device address and other parameters then stick on the label before attaching the Unit.  The 

sticker labels are available on the control panel. Align the Unit and tabs and gently pushing 

the device until it locks into place.  

 

 

 

 

 

 

 

 

 

 

 

Figure 1: Addressable Sounder Circuit Module 

 

Summary of Contents for TX7211

Page 1: ...TX7211 Addressable Sounder Circuit Module Installationand Operation Manual TANDA UK Technology Copyright 2015 All right reserved...

Page 2: ...efore installing the module to ensure proper and safe operation of the system European Union directive 2012 19 EU WEEE directive Products marked with this symbol cannot be disposed of as unsorted muni...

Page 3: ...Content 1 Introduction 4 1 1 Overview 4 1 2 Feature and Benefits 4 1 3 Technical Specification 4 2 Installation 5 2 1 Installation Preparation 5 2 2 Installation and Wiring 5 3 Addressable Sounder Ci...

Page 4: ...ore convenient to the installer The unit is compatible to the TX7004 Analogue Intelligent Fire Alarm Control Panel produced by single manufacture Tand to avoid addressable communication compatibility...

Page 5: ...al to consider the requirement of both sides of the Unit to avoid malfunction and typical fault scenario The main caution is to ensure that the voltage rating of the equipment and Unit are compatible...

Page 6: ...device according to the project layout before placing from the Terminal Base Warning Disconnect the loop connection whilst connecting to the handheld programmer 3 2 Write Addressing 1 Connect the pro...

Page 7: ...mode I II III IV can be set in field referring to the corresponding parameters 1 2 3 4 Program the module before installation use proper mode according to the field conditions Mode Address Quantity O...

Page 8: ...s an example the connection is shown in Fig 9 Fig 9 4 General Maintenance 1 Inform the suitable personnel before conducting the maintenance 2 Disable Addressable Zone Monitor Unit on the control panel...

Page 9: ...to keep the Addressable Sounder Circuit Module Unit working in good condition please maintain the equipment continuously according to recommendations from manufacturers and relative nation codes and l...

Reviews: