Tamson Instruments E20 User Manual Download Page 12

 

 

Tamson Instruments bv 

Page

 

12/22

 

 

Van ’t Hoffstraat 12

 

2665 JL Bleiswijk, The Netherlands 
T. 31 (0) 10 522 43 73 

E20 Thermometer man.docx Rev. 3.03 UK  0319

 

 
 

E-mail: [email protected] 
Website: www.tamson.com 

 

VAT: NL 80 66 34 984 B01 

Bank account no.:  

NL28 INGB 0007 350 370 

NL95 RABO  0160100046 

Chamber of commerce 27 16 95 41 

 
 
 
 

ISO 9001 : 2015 
NL/PRO 238239125 

 

 

 

 
 
 

8.7  Uninstall RS232 to USB converter 

 
Use Start,  configuration screen, software. 
 
A list will be displayed. 
 
Select  the  driver,  FTDIUSB  Serial  Converter  Drivers  and 
perform an uninstall. 
 
 
 
 
 
 
 

8.8  Connector cable 

 
 
 
 
 
 
 
 

 

Summary of Contents for E20

Page 1: ...0 10 522 43 73 E20 Thermometer man docx Rev 3 03 UK 0319 E mail sales tamson com Website www tamson com VAT NL 80 66 34 984 B01 Bank account no NL28 INGB 0007 350 370 NL95 RABO 0160100046 Chamber of...

Page 2: ...ECTION 5 7 SPECIFICATIONS 6 7 1 USE CONFORMING TO ASTM E2877 6 7 2 ACCURACY 6 7 3 RESPONSE TIME 6 8 WHAT IS WHAT 8 8 1 START 8 8 2 MENU STRUCTURE 8 8 3 COMMUNICATION 8 8 4 PROTOCOL 9 8 5 SEND AND RECE...

Page 3: ...rming service maintenance or moving the apparatus always disconnect the apparatus at the main s socket Proper skilled and trained personnel are only allowed to operate this equipment Take notice of wa...

Page 4: ...ctly installed The equipment must be operated only by qualified personnel Avoid damage to the equipment or its accessories through incorrect operation 5 INSTALLATION 5 1 Important Tamson Instruments b...

Page 5: ...prevent shock from the thermometer body or sensor Do not drop the thermometer housing Do not drop the thermometer sensor probe The thermometer housing is of thermoplastic and sensitive to heat Preven...

Page 6: ...l thermometers that provide temperature readings in units of degrees Celsius or degrees Fahrenheit or both The thermometer conforms to the highest accuracy class type A of the described 9 classes A to...

Page 7: ...events rapid temperature changes so it looks like the temperature reading is stable This phenomenon gives a technician a false sense of temperature stability It s not a stable temperature but the PT10...

Page 8: ...able to the USB power adapter The thermometer will light up 8 2 Menu structure When switched on select the temperature readout Degree C C Degree F F Digital B 8 3 Communication The communication betwe...

Page 9: ...write bit 1 and 2 00 not used 01 Location is SRAM 10 Location is FLASH 11 Location is external EEPROM bit 3 0 No extra routine 1 Set Real Time Clock Byte 4 Address high byte Byte 5 Address low byte B...

Page 10: ...AT NL 80 66 34 984 B01 Bank account no NL28 INGB 0007 350 370 NL95 RABO 0160100046 Chamber of commerce 27 16 95 41 ISO 9001 2015 NL PRO 238239125 This 32bit HEX data must be converted to a float The v...

Page 11: ...ly 2 minutes the converter is available The thermometer uses a FTDI RS232 to USB converter chip In order to set up the communication this driver should be installed for previous Windows systems So if...

Page 12: ...om Website www tamson com VAT NL 80 66 34 984 B01 Bank account no NL28 INGB 0007 350 370 NL95 RABO 0160100046 Chamber of commerce 27 16 95 41 ISO 9001 2015 NL PRO 238239125 8 7 Uninstall RS232 to USB...

Page 13: ...er offers 3 readings Degree Centigrade indicated with a C Degree Fahrenheit indicated with a F Analog to Decimal binary value indicated with a B A fourth reading degrees Kelvin is optional The tempera...

Page 14: ...with a USB A connector and a RJ45 6 pole connector on the other Next start the program by a double click on the icon on your desktop when you made a shortcut see previous chapter Or simply double clic...

Page 15: ...7 8 Units See table Item 8 9 Coefficient A Float 10 Coefficient B Float 11 Coefficient C Float 12 Coefficient D Float 13 Coefficient E Float Item 7 Settings for decimals 0 No decimals 1 1 decimal 2 2...

Page 16: ...5 points is found the table 1 The colon Temp gives the temperature with an accuracy of 0 001 C over one minute The colon Reading gives the readout on the E20 thermometer This reading also must be stab...

Page 17: ...0 NL95 RABO 0160100046 Chamber of commerce 27 16 95 41 ISO 9001 2015 NL PRO 238239125 After copying each coefficient the value is verified If for some reason the value is not copied correctly into the...

Page 18: ...84 B01 Bank account no NL28 INGB 0007 350 370 NL95 RABO 0160100046 Chamber of commerce 27 16 95 41 ISO 9001 2015 NL PRO 238239125 10 Spare parts list Ordering code Image Description 10T6097 Works cert...

Page 19: ...Chamber of commerce 27 16 95 41 ISO 9001 2015 NL PRO 238239125 Range 40 20 C 0 80 C 20 120 C 40 140 C Two decimal precision 0 02 C probe short 19T4021 19T4022 19T4023 19T4024 Three decimal precision 0...

Page 20: ...s housing Remark Length 39 mm Width 22 mm Height 62 mm Weight 50 grams Power consumption Adapter 5V 20mA Accuracy Resolution 0 001 C 3 Digit reading 0 010 C 2 Digit reading Accuracy stDev 0 01 C 3 Dig...

Page 21: ...9001 2015 NL PRO 238239125 12 Trouble shooting 12 1 Display shows strange characters Unplug thermometer Wait for 60 seconds Reconnect 12 2 Communication gives problems Cables too long Use shorter cab...

Page 22: ...th the provisions of Directive 89 336 EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility The products are in conformity with the following specificatio...

Reviews: