tams elektronik
Multi-Decoder MD-2
English
CV
No. Input value
(Default)
Remarks and tips
Servo follow-
up time
67
0...255 (5)
each step = 100 msec (0.1 sec)
By setting a servo follow-up time you can avoid that the servo signal is switched off
immediately after the regulating time calculated by the deocder has elapsed und thus the
servo movement is interrupted before reaching the stop e.g. after a unscheduled slow run.
Settings for connecting area 2 (operation mode 1)
CV
No. Input value
(Default)
Remarks and tips
On-time of the outputs
Defines how long the switching
impulse is applied / the output is
switched on.
Turnout 1r
31
For use as a
switching
decoder: 0
For use as a
turnout
decoder::
1, 2 ... 255 (3)
Switched on till the next switching
impulse to the same accessory
decoder address
0
Turnout 1g
32
Turnout 2r
33
Turnout 2g
34
100 milliseconds (msec)
1
Turnout 3r
35
200 milliseconds (msec)
2
Turnout 3g
36
300 milliseconds (msec)
3
Turnout 4r
37
...
Turnout 4g
38
25,5 seconds (sec)
255
Caution:
When connecting turnouts, the set on-time has to be
greater than 0! Otherwise the turnouts possibly burn through.
Page 31
!