![tams elektronik LD-G-14 Manual Download Page 20](http://html1.mh-extra.com/html/tams-elektronik/ld-g-14/ld-g-14_manual_3456060020.webp)
LD-G-14
English
Page 47
CV-name
CV-
no.
Input value /
(State of
delivery)
Remarks
Address
1
1, 2, 3 ... 255
(78)
Starting velocity 2
1, 2, 3 ... 80
(16)
=The voltage to be output to the
motor at speed level 1.
The value "0" corresponds to 0
Volt, the value "80" to the max.
voltage.
Acceleration
delay
3
1, 2, 3 ... 80
(5)
= Length of the delay before the
switching to the next higher
speed level when the locomotive
is accelerating.
Braking delay
4
1, 2, 3 ... 80
(5)
= Length of the delay before the
switching to the next lower
speed level when the locomotive
is braking.
Maximum
velocity
5
1, 2, 3 ... 63
(54)
= The voltage to be output to
the motor at the highest speed
level.
Analogue mode 6
2, 3 (3)
2=on, 3=off
7
---
Only internal importance. Do not
enter new values for this CV.
Reset
8
1, 2, 3 ... 255
(---)
Any value restores the settings
in state of delivery.