LD-G-10
English
Page 47
!
Switching the shunting gear
In Motorola II format the shunting gear can be switched on and off via
the auxiliary function F4. In Motorola I format the shunting gear cannot
be activated.
FAQ
§
Parts are getting too hot and/or start to smoke.
Disconnect the system from the mains immediately!
Possible cause: One or more connections are soldered incorrectly.
à
Check the connections.
Possible cause: The connection of the motor is connected to locomotive
ground.
à
Disconnect the connection from locomotive ground.
§
After programming the decoder the locomotive does not run or runs
badly.
Possible cause: The set values for the CV are inconsistent.
à
Perform a decoder reset and program the decoder anew.
§
The locomotive does not run in analogue mode.
Possible cause: The analogue mode is switched off.
à
Alter the value
for CV #6.
Possible cause: The analogue model railway layout is run with a D.C.
speed control; the analogue mode however is only possible with
A.C. speed controls.
§
In digital mode the locomotive suddenly runs very fast.
Possible cause: Interfering signals from the layout have switched the
decoder to analogue mode.
à
So long as the interfering signals´
origin cannot be found it is advisable to switch off the automatic
recognition of the analogue mode during digital operation.
§
The locomotive runs too fast or too slow.
Possible cause: Different locomotives drive differently with the same
decoder settings.
à
Adjust the decoder settings to the individual
driving characteristics of the locomotive.