tams elektronik
English
FD-R Extended
Basic settings
Name of CVs /
registers
No. Input value
(Default)
Remarks and Tips
RailCom
settings
28
0, 1, 2, 3
(3)
0 = no feedback
1 = channel 1 on only
2 = channel 2 on only
3 = channel 1 and 2 on
Configuration
data 1
29
0 ... 64
(14)
Direction "Standard"
0
Reverse direction
1
14 speed levels
0
28 or 128 speed levels
2
Analoge recognition off
0
Analoge recognition on
4
RailCom off
0
RailCom on
8
Linear velocity characteristic
0
Alternat. velocity charact.
16
Basic addresses
0
Not for MM mode: Extended addresses
32
Example: CV#29 = 0.
à
Direction = "Standard". 14 speed levels. Basic addresses. Automatic
analogue recognition = "off". RailCom = "off".
Example: CV#29 = 46.
à
Direction = "Standard". 28 or 128 speed levels in DCC-mode. Automatic
analogue recognition = "on". RailCom = "on". Extended addresses.
Tip: If the use of extended addresses is activated in CV#29, the decoder does not react to
signals in Motorola format!
Switching off
at overload
48
--- (64)
Determines, at which current
the overload protection
responds. The higher the input
value, the higher is the current
responding at overload
protection.
64 = 1 500 mA
The value of 64 should be
altered as an exception only!
Page 38