Booster B-4
English
7. Settings
The booster B-4 can be set to individual requirements by programming
on main (POM) or by inserting short-circuit terminations (jumpers).
Possible settings
Manu-
facturers
settings
Setting
with
jumpers
Track voltage
10 – 24 V, to be set
in 1 V-steps
18 V
yes,
16 – 22 V
Autostarting time
after a short circuit
4 – 10 Sek., to be
set in 1 sec.-steps
4 sec.
4 sec.or
10 sec.
Max. track current
(interrupting
current after a short
circuit)
2 – 5 A,
to be set in
1 A-steps
5 A
yes
RailCom
active or inactive
active
no
Switching off with a
DCC points
switching command
active or inactive /
assigning the points
address
inactive
no
Watchdog
active or inactive /
assigning the points
address
inactive
no
Limiting value for
short circuit
warning
0,2 – 1 A,
to be set in
0,2 A-steps
0 A
inactive
no
Autostarting time
after 5 short circuits
10 – 100 sec.
60 sec.
no
Page 17