8. Check list for troubleshooting
Bus voltage in the sublevel is faulty.
Display: LED "Power SUB-BiDiB" flashes quickly.
Possible cause: The supply voltage is not sufficient (below 12 V).
Check the connected power supply unit. The required output voltage
is 12 to 18 V DC.
Possible cause: The current consumption of all components on the
sublevel which are supplied via the bus line is more than 500 mA.
Check the current consumption of the components. If necessary
connect an additional power supply (e.g. BiDi-Power, art. no. 46-09016
or 46-09017).
Registration at the BiDi-Bus is rejected.
Display: Double flashing of the LED "Identify".
Possible cause: More than 32 components (including ARTEMIS) are
connected to the BiDi-Bus in the main level.
Check the number of
components.
Possible cause: The power supply collapsed during the login process.
Check whether the power supply unit is functional or overloaded.
The data is not transferred correctly.
Possible cause: The connection(s) between ARTEMIS and the other
BiDiB nodes are interrupted.
Check the connection(s).
Possible cause: The terminating jumpers are not plugged in although
ARTEMIS is installed at the end of one or both BiDiB lines or
The termination jumpers are plugged in, although ARTEMIS is not
installed at one end of one or both BiDiB lines.
Check the
arrangement of the termination jumpers.
Page 18