LD-G-24
English
Page 43
CV-name
CV-
no.
Input value /
(State of
delivery)
Remarks
Assignment
0 ... 31
Numerical value *
2
F0 – F4 to
Operation with:
the outputs:
---
0
X4
55
(16)
function key F1
1
X5
56
(16)
function key F2
2
X6
57
(1)
function key F3
4
X7
58
(2)
function key F4
8
function key F0
16
Parameter of
load control KI
59
0 ... 255
(5)
= Integral component of the
load control.
Effects
0 ... 255
Numerical value *
2
for the
Flickering active
1
outputs:
Strobe active
2
X4
60
(16)
MARS light active
4
X5
61
(8)
at backward motion inactive 8
X6
62
(0)
at forward motion inactive 16
X7
63
(0)
Flashing 2 Hz phase A
32
Flashing 2 Hz phase B
64
Flashing 1 Hz
128
Parameter of
load control KD
64
0 ... 255
(16)
= Differential component of the
load control
Alternative
velocity
characteristic
(only with
mode 28
speed levels)
67
.
.
.
.
94
0 ... 255
= The velocity table for the
alternative velocity characteristic.
Any motor voltage can be
assigned to all of the 28 speed
levels.
The value "0" corresponds to a
voltage of „0“, „255“ to the
maximum voltage.