Wiring 

Important

- Wiring the HV is different than a normal ON/OFF fan. Because the doors are motorized, they

need power to open and power to close.   The HV requires a constant source of power. The fan operation is
controlled internally. Please follow the instructions carefully.  It is recommended that the wiring of the HV be
done by a licensed electrician.

Be sure to turn off power before wiring the HV Whole House Fan

HV1000

HV1600 (Optional Wiring)

Hardwiring the unit to wall switches using the

BLUE and YELLOW wires will provide addi-

tional, manual control. Using these switches 

will override the remote control function.

The HV whole house cooling fans are not

for use with solid state speed controls

HV1000 ........................................78 Watts
HV1600.......................................140 Watts

HV1000 .......................................1150 CFM
HV1600 High..............................1600 CFM
HV1600 Low ...............................1150 CFM

Operating your HV  

Important

Be sure at least one window is open when the fan is operating.

HV1000

- The HV1000 is operated by the wall switch (not included) installed per the

wiring instructions. An optional remote control kit is available (Part# TTi-HVRC). 

HV1600

- The HV1600 is controlled by the hand held remote transmitter. Additional

controls, when used, may override the remote control. See the Wiring section of this
manual for further details. 

HV1000 & HV1600.........................R-38

Summary of Contents for HV1000

Page 1: ...rea Make sure that there is adequate clearance above the fan for the doors to open The minimum requirement is 12 If your home has an engineered roofing system care should be taken that the HV will fit within the truss layout WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING Use this unit in the manner intended by the manufacturer If you have any questions...

Page 2: ...panel and any strapping within the frame Do not damage electri cal wiring or other hidden utilities 3 Install a foam weather stripping or other flexible material not sup plied on the top of the joists and added framing This will serve to seal between the housing and the framing as well as dampen vibra tions Check the joint between the ceiling and the 2x stock Some types of ceilings are spaced away...

Page 3: ...ovide addi tional manual control Using these switches will override the remote control function The HV whole house cooling fans are not for use with solid state speed controls HV1000 78 Watts HV1600 140 Watts HV1000 1150 CFM HV1600 High 1600 CFM HV1600 Low 1150 CFM Operating your HV Important Be sure at least one window is open when the fan is operating HV1000 The HV1000 is operated by the wall sw...

Page 4: ...ill make it hot when the switch is closed HV1600 If the wireless remote fails to activate the fan the battery may need replacing The transmitter uses a type A23 12V battery Remove the back plate from the transmitter and remove the battery Following the markings replace the battery Secure the back plate to the transmitter 320 Main Street Buzzards Bay Ma 02532 508 759 4660 800 222 5932 Fax 508 759 6...

Reviews: