background image

Electrical:

Voltage

Power

Air Flow 

Operation

Insulation Value of

Closed Doors

Weights

Top Housing

Lower Housing

115 VAC 60Hz

(High Speed) 450 Watts
(Low Speed) 340 Watts

High Speed 3400 CFM
Low Speed 1900 CFM

30 second Door Cycle Time
(Open-Close)

Model:Ghost  R-38 
Model:Ghost/R50  R-50 

Whole House Ventilator: 48 Lbs.
Shipping: 71 Lbs. (2 boxes)

26 1/4” L x 26” W x 14 1/8” H

25 7/8” L x 29 1/2” W 
x 13 5/8” H

specificationS

GHOST-Optional wiring
for fan operation

(control not included)

WARNINGS:

State and local 

electrical codes may require that

the GHOST be installed 

by a licensed electrician. 

Check with your local code 

officials before installing. 

The GHOST is not for use 

with solid state controls.

Be sure to turn off power 

before wiring the GHOST.

Figure 6.

Figure 7.

6. Rotate the upper housing until it lines up with the
lower housing.  Make sure the edges of the two hous-
ings mate all the way around the GHOST (Figure 6)
and then pull the black attachment handles down over
their attachment posts (Figure 7). 

7. If desired, secure the GHOST to the top of the joists.

8. Plug the connector from the GHOST into the Control
Box.  Plug  the  Control  Box  into  an  unswitched,
grounded receptacle.

9. Install the ceiling grille (screws provided).

10. Check the unit for proper operation.

Operating your GHOST 

Important 

- Be sure at least one window is open when the

fan is operating. The GHOST is controlled by the hand held
remote transmitter. The transmitter has two buttons; ON/OFF
and  LO/HI.  LO/HI  controls  the  speed  of  the  fan.  See  the
Wiring section of this manual for further details.

The line cord must 

remain plugged into 

a constant HOT outlet.

Hardwiring the unit to controls using the YELLOW, BLACK and
BLUE wires will allow for additional, manual operation. Use of
controls will override remote control functions. Recommended
controls are SPST switches and/or non digital spring wound
timers. Use of other controls will void the warranty.

Summary of Contents for GHOST GH-08

Page 1: ...tem care should be taken that the GHOST will fit within the truss layout READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING Use this unit in the manner intended by the manufacturer If you have any questions contact the manufacturer Before servicing or cleaning unit switch power off at service panel and lock service panel to...

Page 2: ...the proper sized hole in the ceiling is cut a pilot hole under where the fan will be installed Figure 2 From above using a saw cut along the inside edge of the framework removing the ceiling panel and any strapping within the framework Do not damage electrical wiring or other hidden utilities 3 Install a foam weather stripping or other flexible mate rial not supplied on the top of the joists and a...

Page 3: ... two hous ings mate all the way around the GHOST Figure 6 and then pull the black attachment handles down over their attachment posts Figure 7 7 If desired secure the GHOST to the top of the joists 8 Plug the connector from the GHOST into the Control Box Plug the Control Box into an unswitched grounded receptacle 9 Install the ceiling grille screws provided 10 Check the unit for proper operation O...

Page 4: ...OR THE PRODUCT SHALL BE LIMITED TO THE REPLACEMENT VALUE OF THE PRODUCT IN NO EVENT SHALL TAMARACK TECHNOLOGIES INC BE LIABLE FOR ANY INCIDENTAL DAMAGES OR FOR ANY CONSEQUENTIAL PROPERTY OR COMMERCIAL DAM AGES IRRESPECTIVE OF THE CAUSE THEREOF OCCURRING EITHER DURING OR AFTER THE WARRANTY PERIOD INCLUDING WITHOUT LIMITATION ANY DAMAGES TO ANY PART OF A BUILDING OR ITS CONTENTS NOTE SOME STATES DO ...

Reviews: