![Tamarack Solar 90286 Installation Manual Download Page 8](http://html1.mh-extra.com/html/tamarack-solar/90286/90286_installation-manual_815710008.webp)
TTP-23-MAN
Pole Mount - TTP Series
7
Step Three - Assemble Adjuster Arm
• Install the Adjuster Arm as shown in the image below. Attach it to the Support Pipe that does not go through
the holes in the Pole Cap with a 2-3/8-inch U-bolt and two fl ange nuts. Tighten hand tight to allow it to be
alligned with the tab on the Pole Cap Backplate.
• Attach the Adjuster Arm to the tab provided on the Pole Cap Backplate with a 1/2-13 x 1-1/2-inch bolt and
nut.
• Use the hole that makes the Rail Support Blades approximately horizontal for assembly purposes. Th
is will be
readjusted in fi nal assembly.
Step Four - Module Mounting Rail Assembly
(for TTP-3 only)
• Assemble a 127.5-inch Module Mounting Rail by splicing an 85-inch rail and a 42.5-inch rail section using a
rail splice and two 5/16” x 1.125-inch bolts and channel nuts. Slip the splice 5-inches into the end of one rail
section, place a channel nut and bolt approximately 2.5-inches from the end and tighten. Slide the second rail
section over the splice, butting the rail section ends together, and repeat this process
• Tighten Splice Bolts to 12 ft -lb. If a Module Clamp needs to be placed between the two Splice Bolts, they will
need to be loosened to allow it to be inserted.
• Repeat this process for the second Module Mounting Rail.