Interfaces
User guide
172
ENQ/STX protocol
In addition to this XON/XOFF message, the possibility exists of re-
questing a status byte from the printer using the ENQ code (hex. 05,
dec. 5). The STX code (hex 02, dec. 2) is used to clear any error
messages (parity error, buffer overflow).
STX (hex02)
Clears any previous parity or framing error as well
as any buffer overflow error.
ENQ (hex05)
The current printer status is sent to the host.
XON/XOFF
This protocol is automatically used for data flow
control and printer status handling.
HandThr.=ON
The STX and ENQ characters are not filtered out
of the data stream and control the interface in ad-
dition.
HandThr.=OFF The STX and ENQ are filtered out of the data st-
ream and handled immediately by the interface.
ETX/ACK protocol
ETX (hex03)
Block end character
ACK (hex06)
Acknowledgement informing the host that further
data may be transmitted.
XON/XOFF
This protocol is used in addition to data flow con-
trol and printer status handling.
HandThr.=ON
An ETX is not acknowledged by ACK before all
previously arrived data have been printed.
HandThr.=OFF When the printer receives an ETX, it returns an
ACK to the host. Any previously sent data or
blocks may still be present in the printer buffer.
Status byte
Bit 0 – 1
BUSY
Bit 1 – 1
Off Line
Bit 2 – 0
Paper end
Bit 3 – 1
Always 1
Bit 4 – 1
Cover open
Bit 5 – 1
Buffer overflow
Bit 6 – 1
Parity or frame error
Bit 7 – 0
Always 0
Summary of Contents for T2265plus
Page 1: ...User guide T2265 T2280 Matrix printer...
Page 2: ......
Page 16: ......
Page 40: ......
Page 56: ......
Page 66: ......
Page 104: ...The Menu User guide 94 Menu settings example...
Page 105: ...User guide The Menu 95...
Page 106: ......
Page 126: ......
Page 136: ......
Page 148: ......
Page 186: ......
Page 193: ...User guide Index 183 W Width 87 Wrap 109 X XON XOFF 171...
Page 194: ......