background image

Please note:

In general, the addressing of the RCU is automatically performed. Only in case the RCU is manually addressed,
the serial number written on the product label has to be extended by the corresponding colour coding extension
(e.g. CSG351234-

R1

). If the connected antenna has no RFID spindles, the serial number has to be extended by

“-XX“ instead of the colour coding extension (e.g. CSG351234-

XX

)

Please note:

Additional grounding of the RCU is not required if the RCU is fixed to an antenna with proper ground-
ing. Please assure that grounding of the antenna has been carried out according to all relevant local
regulations.

Please note:

As a result of more stringent legal regulations and judgements regarding product liability, we are
obliged to point out certain risks that may arise when products are used under extraordinary operating
conditions.

The mechanical design is based on the environmental conditions as stipulated in ETS 300 019-1-4 and thereby
respects the static mechanical load imposed on an antenna by wind at maximum velocity. Wind loads are
calculated according to DIN 1055-4. Extraordinary operating conditions, such as heavy icing or exceptional
dynamic stress (e.g. strain caused by oscillating support structures), may result in the breakage of an antenna or
even cause it to fall to the ground. These facts must be considered during the site planning process.

The installation team must be properly qualified and also be familiar with the relevant national safety
regulations.
The details given in our data sheets have to be followed carefully when installing the antennas and
accessories.
The limits for the coupling torque of RF-connectors, recommended by the connector manufacturers
must be obeyed.

Any previous datasheet issues have now become invalid.

Page 2 of 5

86010148

V01

9

3

6

.4

6

2

4

/e

S

u

b

je

c

t

to

a

lt

e

ra

ti

o

n

.

Remote Control Unit (RCU)

Description of the adjustment mechanism (protective cap removed):

1

Adjustment wheel with twist-
lock function.

2

Downtilt spindle with integrated

scale.

1

Thread for fixing the protective
cap or the RCU (Remote Control
Unit).

2

Gearwheel for RCU power drive.

To set the downtilt angle exactly,
you must look horizontally at the
scale. The lower edge of the gear-
wheel must be used for alignment.

1

2

2

1

All specifications are subject to change without notice.

Questions? Visit www.Talleycom.com or contact Talley at 800.949.7079 or [email protected] today.