Talkpool 0786767169876 User Manual Download Page 12

OY1110 LoRaWAN Temperature and humidity sensor, User manual, Version 1.0 
 

12 

7

 

Product life length 

The OY1110 LoRaWAN Temperature and Humidity sensor is design for 10+ years of 

maintenance-free operation. The product has high quality, high capacity batteries which 

support 15 min interval transmission at SF10 for 10 years. The product has soldered battery to 

prevent problems with corrosion and oxidation on the battery terminals, which is a common 

problem for batteries in field.  

The protocol support also over the air adjustable measurement interval, and grouping 

function, which enables flexible usage to optimize the product for fine time resolution or 

extended life length.  

8

 

Security 

The OY1110 is based on the Talkpool LoRaWAN platform, with state-of-art security 

solution. The device has secure boot, to ensuring the firmware integrity, prevents malware 

injection and modification. The encrypted firmware prevents from any backwards engineering 

to engineer attack vectors. 

The security keys are generated and stored in an ultra-secure cryptographic co-processor and 

cannot be extracted from the device. 

The device is locked down in full security state, to keep the integrity and privacy of the 

customer data. 

 

9

 

Protocol 

The protocol consists of different types of data 

-

 

LoRaWAN v.1.0.4 standard commands  

-

 

Unsolicited uplink status commands during configure state 

-

 

Periodic measurement reports 

-

 

Downlink commands and queries 

-

 

Uplink query response 

Note 0x denotation means hexadecimal encoded. 

 

9.1

 

LoRaWAN standard commands 

All standard LoRaWAN v 1.0.4 are supported. Please refer to the LoRaWAN standard for the 

protocol definition. 

Summary of Contents for 0786767169876

Page 1: ...OY1110 LoRaWAN Temperature and humidity sensor User manual Version 1 0 January 2019...

Page 2: ...ct life length 12 8 Security 12 9 Protocol 12 9 1 LoRaWAN standard commands 12 9 2 Unsolicited uplink status commands 13 9 3 Periodic measurement reports 13 9 3 1 Periodic single measurement report 13...

Page 3: ...on contained herein 1 1 Technical support Please visit www talkpool io for additional information or contact IoT support talkpool com 1 2 EU Declaration of conformity EC DECLARATION OF CONFORMITY cert...

Page 4: ...g all phases of the operation usage service or repair of this Talkpool product Read the product manual Do not modify the product The product should not be exposed to extreme heat or open flame The dev...

Page 5: ...to a collection point designated for the recycling of electrical and electronic appliances Separate collection and recycling of your waste at the time of disposal will contribute to conserving natura...

Page 6: ...or is designed to measure temperature and humidity in indoor environments The sensor is intended for climate control energy optimization and damage preventions in attics and basements It is optimized...

Page 7: ...e UP arrow upwards It can be mounted either with screws or adhesive tape Figure 3 Push button and LED The top piece contains all active components The unit is shipped in sleep mode i e with all functi...

Page 8: ...e Talkpool OUI range The device is configured with device unique DevEUI and AppKey The device is default configured for OTA provisioning Contact the Talkpool team for ABP configuration The device foll...

Page 9: ...ration by polling server after configuration commands during 2 minutes This is done by sending uplink status command 0x20 1 long flash 2 sec Operational Joined to a LoRaWAN network measures temperatur...

Page 10: ...vity Network LoRaWAN Frequency bands 868 MHz Provisioning Over the air personalization Security Algorithms AES 128 Hardware Cryptographic co processor Features Secure boot Secure firmware upgrade Hard...

Page 11: ...OY1110 LoRaWAN Temperature and humidity sensor User manual Version 1 0 11 Unique App EUI available upon request Enclosure IP30 Certifications RoHS compliant CE LoRaWAN...

Page 12: ...Talkpool LoRaWAN platform with state of art security solution The device has secure boot to ensuring the firmware integrity prevents malware injection and modification The encrypted firmware prevents...

Page 13: ...contact Talkpool support 9 3 Periodic measurement reports The sensors transmit periodic unsolicited measurement reports either from a single measurement or grouping several measurements to one transm...

Page 14: ...her explained in chapter 9 3 3 Measurement value and chapter 9 3 4 Grouping header 9 3 3 Measurement value The measurement value for each measurement is sent as two unsigned 12 bit values coded in thr...

Page 15: ...an 8 bit unsigned value If bit7 the most significant bit is cleared 0 the other 7 bits bit0 bit6 indicates the number of minutes between two measurements If bit7 the most significant bit is set 1 the...

Page 16: ...es ago 9 4 Downlink commands and queries To control the sensor application in band commands and queries can be sent from the server application Contact your LoRaWAN network provider for in band applic...

Page 17: ...h 50 C offset Approximately 5 C accuracy 1 0x20 Status Uint8 Bitfield Query Yes For Talkpool support troubleshooting Cleared through reset 1 0x23 Measurement interval Uint16 Big endian Minutes 1 10080...

Page 18: ...re supported Maximal interval is 168 hours i e 7 days 9 5 2 TX group size Several measurements can be grouped into a group measurement report to save battery The TX group command defines how many meas...

Page 19: ...ion Note Type 1 xx 0x01 Data 0x02 Command NACK Index 1 xx Command Index Data As defined for Command Index only for Type Data 9 6 1 Uplink status report The uplink status report is sent unsolicited dur...