Product life length
The OY1110 LoRaWAN Temperature and Humidity sensor is design for 10+ years of
maintenance-free operation. The product has high quality, high capacity batteries which
support 15 min interval transmission at SF10 for 10 years. The product has soldered battery to
prevent problems with corrosion and oxidation on the battery terminals, which is a common
problem for batteries in field.
The protocol support also over the air adjustable measurement interval, and grouping
function, which enables flexible usage to optimize the product for fine time resolution or
extended life length.
8
Security
The OY1110 is based on the Talkpool LoRaWAN platform, with state-of-art security
solution. The device has secure boot, to ensuring the firmware integrity, prevents malware
injection and modification. The encrypted firmware prevents from any backwards engineering
to engineer attack vectors.
The security keys are generated and stored in an ultra-secure cryptographic co-processor and
cannot be extracted from the device.
The device is locked down in full security state, to keep the integrity and privacy of the
customer data.
9
Protocol
The protocol consists of different types of data
-
LoRaWAN v.1.0.4 standard commands
-
Unsolicited uplink status commands during configure state
-
Periodic measurement reports
-
Downlink commands and queries
-
Uplink query response
Note 0x denotation means hexadecimal encoded.
9.1
LoRaWAN standard commands
All standard LoRaWAN v 1.0.4 are supported. Please refer to the LoRaWAN standard for the
protocol definition.