TOWER PARTS Kit Installation Instructions
Page
2
of
4
Rev. 1/26/2017
Copyright 2017 Talkaphone
• 7530 North Natchez Avenue • Niles, Illinois 60714 • Phone 773.539.1100 • [email protected] • www.talkaphone.com.
All prices and specifications are subject to change without notice. Talk-A-Phone, Scream Alert, WEBS and WEBS Contact are registered trademarks of Talkaphone All rights reserved.
Figure 1
: Tower Installation
To insure proper grounding of all electrical components, the tower mount should be
effectively earth grounded from the grounding stud (located in the electrical box) with 6
AWG or better insulated, stranded copper wire to the metallic power service raceway
(conduit) or an 8' or longer corrosion-resistant ground spike
.
4.
After removing the access panel
from the tower’s rear access opening, install the tower onto the bolts
with the emergency phone opening oriented in the desired direction. Install second set of
3/4”-10 hex
nuts and washers. Tighten the upper nuts; the bottom set is only for leveling.
5.
Wire incoming power to the LED Blue Light and to the LED Panel Light. The LED Panel Light operates
on 12VDC up to 120VAC and is not polarity sensitive. The high voltage LED Blue Light operates only
on 120VAC. The low voltage LED Blue Light, if used, operates on 12/24VDC or 24VAC only. Please
refer to the wiring instructions as shown in
Figure 2
and
Figure 3
.
Figure 2
: Electrical connections to the ETP-EL LED Blue Light