Voice Message Codes
Voice messages allow for a pre-recorded message to play automatically when the answering point
(receiving end) answers the call. Typically, physical location information is provided through this voice
message to identify the unit to the answering point. The maximum length of a voice message is 16
seconds.
The voice message code is comprised of six (6) digits in the following format
—parameters A through F
are defined in the table below:
A B C D E F # 1 7
The factory default timing/dialing code is:
0 0 1 2 1 0 # 1 7
Parameter
Function Description
Values
Definition
A + B
Two-Digit Voice Message
Delay.
Sets the amount of time
required to elapse (1-99
seconds) after dialing the phone
number before the voice
message plays.
Factory set to automatically start
playing the voice message after
the AOR Series Analog Station
has determined the call has
been answered.
Important Note:
If this delay is
used, adequate time must be
allowed for the unit to detect
ring-no-answer and busy signals
when used in conjunction with
redial features.
00
Play automatically
[Default]
01
1 second
02
2 seconds
…
…
98
98 seconds
99
99 seconds
C
Repeat Voice Message.
The
AOR Series Analog Station can
be programmed to play the voice
message from 1-9 times, or to
continuously repeat the voice
message every 8 seconds until a
touch tone
*
is detected from the
answering point. The
“ANSWERED”
LED will turn on
automatically after the voice
message has stopped repeating.
0
Repeat every 8 seconds
1
Play 1 time
[Default]
2
Play 2 times
…
…
8
Play 8 times
9
Play 9 times
D
Hang Up on Return to Dial
Tone.
If enabled and a return
dial tone is detected, the AOR
Series Analog Station will hang
up.
1
Disabled
2
Enabled
[Default]
E
Double Ring Cadence Mode.
The AOR Series Analog Station
can be programmed to
recognize the double ring
cadence that is outputted by
many phone systems. If the
AOR Series Analog Station is
connected to an extension that
provides a double ring cadence,
then enabling this mode will
1
Disabled
[Default]
2
Enabled
NOTE:
The voice message feature is
NOT
supported on calls placed via the Auxiliary Input.