background image

    

INSTALLATION  MANUAL FOR CRYSTALLINE SOLAR PHOTOVOLTAIC MODULES 

     

Version: A2         Effective Date: May 13, 2015 

 

ZHONGLI TALESUN SOLAR COMPANY LIMITED 

Address: No. 1 Talesun Road, Changkun Industrial Park, Shajiabang Town, Changshu, Suzhou, Jiangsu Province, 215542, P.R.China 

Website: 

www.talesun.com

    Email: 

[email protected]      

 Tel: +86 400 885 1098 

10 / 19 

 

 

4.4

 

GROUNDING  

 

The module frame must be properly grounded. The grounding wire must be properly fastened 
to the module frame to assure good electrical contact. Use the recommended type, or an 
equivalent, connector for this wire. 

 

Polarity negative ground of the inverter in the system is able to effectively avoid the PID 
phenomenon of the module in addition, and professional person is needed to undertake the polarity negative ground 
operation of the inverter. 

 

If the support frame is made of metal, the surface of the frame must be electroplated and have excellent conductivity.  

 

Grounding clip assembly (TYPE: TYCO ELECTRONICS 1954381-2).  

Wire selection and preparation:  

The grounding clip accepts solid uninsulated copper wire sizes 10 or 12 AWG. The wire must not be nicked, cut, or 
scraped. There is no preparation required. 

Spacing:  

Care must be used to avoid interference between adjacent grounding clips and other components for removal of the 
grounding clip. 

Removal:  

The wire can be removed from the grounding clip when the slider is disengaged (slider and screw are exposed). The 
screw must be loosened before the grounding clip can be removed from the frame. The grounding clip can be reused 
up to 5 times after proper removals (the 8--32 screw and hex nut or Keps nut can be reused; however, the thread-
cutting screw must be replaced). The thread-cutting screw cannot be reused after removing the grounding clip from 
the frame. 

Repair:  

The grounding clip is not repairable. Discard any defective or damaged grounding clips. 

Tooling:  

A drill bit is required for drilling the frame holes. A No. 2 cross--recessed screwdriver must be used to secure (and 
remove) the screw of the grounding clip to (and from) the frame. For the grounding clip with the 8--32 screw and hex 
nut or Keps nut, a 3/8--in. wrench must be used to secure (and remove) the nut of the grounding clip to (or from) the 
frame. The recommended screw tightening torque is 1.7+0.5/-0.2Nm (15+4.4/-1.7 in.-lbs). 
 
The slider can be engaged manually or channel lock pliers can be used to engage the slider. A flat—head screwdriver 
must be used to disengage the slider. 

 

Summary of Contents for TP672M-330

Page 1: ...kun Industrial Park Shajiabang Town Changshu Suzhou Jiangsu Province 215542 P R China Website www talesun com Email sales talesun com Tel 86 400 885 1098 INSTALLATION MANUAL For crystalline solar phot...

Page 2: ...POSE OF THE MANUAL 1 2 DISCLAIMER OF LIABILITY 1 3 PRODUCTION IDENTIFICATION 2 SAFETY GUIDELINES 2 1 GENERAL SAFETY GULDELINES 2 2 PRODUCT PRECAUTION 2 3 TRANSPORT AND STORAGE SAFETY GUIDELINES 3 MECH...

Page 3: ...f the solar installation Information for operators Keep these instructions safe for the entire useful life of the solar installation Please contact your plant supplier for information concerning the f...

Page 4: ...eries Cover the solar modules with opaque material for the entire duration of assembly Only then is the module reliably de energized Never disconnect plugs when under load Be aware that even without t...

Page 5: ...es or improper storage Ensure modules do not bow under their own weight Do not rest a module unprotected on its edges This can damage the module and the frame Do not lift or move the modules using the...

Page 6: ...stem The modules may be installed in landscape or portrait format Install the module in such a way that the junction box is positioned in the upper area of the module and the wires hang downwards The...

Page 7: ...frame Modules should be bolted to support structures through mounting holes located in the frame s back flanges only Do not drill additional holes Doing so will void the warranty Each module must be s...

Page 8: ...ructions above b Clamping installation Modules can be installed with clamps Modules must be securely attached to the mounting structure with four clamps on the long frame The modules must be properly...

Page 9: ...990mm 40mm 2400Pa 250mm 100mm 5400Pa 250mm 100mm TP648 series 1324mm 990mm 35mm 2400Pa 200mm 100mm 5400Pa 200mm 100mm 1324mm 990mm 40mm 2400Pa 200mm 100mm 5400Pa 200mm 100mm TP572 series 1580mm 808mm...

Page 10: ...nsure that the construction or structure roof facade support etc where the modules are being installed is strong enough to support the weight of the modules and all other system components If modules...

Page 11: ...ed There is no preparation required Spacing Care must be used to avoid interference between adjacent grounding clips and other components for removal of the grounding clip Removal The wire can be remo...

Page 12: ...rsion A2 Effective Date May 13 2015 ZHONGLI TALESUN SOLAR COMPANY LIMITED Address No 1 Talesun Road Changkun Industrial Park Shajiabang Town Changshu Suzhou Jiangsu Province 215542 P R China Website w...

Page 13: ...Date May 13 2015 ZHONGLI TALESUN SOLAR COMPANY LIMITED Address No 1 Talesun Road Changkun Industrial Park Shajiabang Town Changshu Suzhou Jiangsu Province 215542 P R China Website www talesun com Ema...

Page 14: ...ever doing so will void warranty unless this exchange is made by an authorized person Protect yourself from electric shocks while debugging or maintaining the solar power system 5 2 TROUBLESHOOTING DA...

Page 15: ...Mono crystalline 5inch 72cells Mono crystalline Dimension mm 1960 990 40 1960 990 45 1960 990 50 1640 990 35 1640 990 40 1580 808 35 1580 808 40 Weight kg 24 19 14 7or15 Module Type TP672P TP660P TP6...

Page 16: ...290 1000 IEC 290 36 4 7 97 45 3 8 63 TP672M 285 1000 IEC 285 36 2 7 88 45 2 8 53 TP672M 280 1000 IEC 280 36 2 7 74 45 1 8 41 TP660M 275 1000 IEC 275 31 1 8 85 38 3 8 95 15 TP660M 270 1000 IEC 270 31 8...

Page 17: ...290 35 9 8 09 44 7 8 72 TP672P 285 1000 IEC 285 35 8 7 97 44 6 8 65 TP672P 280 1000 IEC 280 35 7 7 86 44 5 8 56 TP672P 275 1000 IEC 275 35 5 7 76 44 4 8 49 TP672P 270 1000 IEC 270 35 4 7 64 44 3 8 4 T...

Page 18: ...215542 P R China Website www talesun com Email sales talesun com Tel 86 400 885 1098 17 19 TP572M 205 1000 IEC 205 37 5 5 49 45 7 5 92 TP572M 200 1000 IEC 200 37 3 5 42 45 5 5 85 TP572M 195 1000 IEC...

Page 19: ...86 400 885 1098 TEL 86 512 8235 5888 FAX 86 512 8235 5588 JAPAN 6F 3 22 1 Toranomon Minato ku Tokyo Japan 105 0001 Email japan talesun com Web www talesun com jp T 03 5733 3498 F 03 34341515 USA 111 W...

Page 20: ...s No 1 Talesun Road Changkun Industrial Park Shajiabang Town Changshu Suzhou Jiangsu Province 215542 P R China Website www talesun com Email sales talesun com Tel 86 400 885 1098 19 19 THAILAND Thai C...

Reviews: