6. How to Set the Unit

 

 

6.1 Control Panel 

 

 
6.2 Main Function 

 

Your Talent Sound & Lighting fixture may be operated as a stand-alone 
device that runs on pre-programmed routines or sound activation, in 
master/slave mode with other devices, or via an external DMX512 
controller. In DMX mode it is configurable to be controlled by 3, 5, or 7 
channels.  
 
Besides stand-alone operation, there are two main ways to control the 
fixture: 

A. Universal DMX control mode 
B. Master/Slave operation 

 
A. Universal DMX controller 

This fixture's DMX address can be set remotely by a universal DMX 
controller. First, you need to program two scenes into a chase, and then 
link the fixtures to the universal DMX controller. When you run the chase, 
the fixtures in the chain will set the series DMX address automatically. 
Each lighting fixture needs to have an address set when in DMX mode, to 
receive the data sent by the controller. The address number is between 0-
511 (usually 0 & 1 are equal to 1). Please refer to the following diagram to 
set the address for the first four units. 
 

 

The numbers 1, 5, 9, and 13 indicate the starting address of each of the 
fixtures. 
 

B. Master/Slave operation 

The fixture allows you to link as many as 16 fixtures together and operate 
without a controller. In Master/Slave mode, the first fixture will control 
the others to give an automatic, sound activated, synchronized light show. 
This function is good for when you want an instant performance. The first, 
or master, fixture's DMX input will have nothing connected to it. Its 
output connects to the slave fixtures, which will be set in slave mode 
automatically. 

 
 
 
 
 
 

Summary of Contents for LP64LED-FLAT

Page 1: ...1 Safety Instructions 2 Technical Specifications 3 Installation 4 How to Connect the Fixture 5 DMX512 Connections 6 How to Set the Unit 7 DMX Configuration 8 IR Remote Control 9 Troubleshooting 10 DMX General Information ...

Page 2: ...might be a hazard of electrical shock To prevent or reduce the risk of electrical shock or fire do not expose the fixture to rain or moisture The fixture must be replaced if there is visible damage to the housing Do not look directly at the LED light beam while the fixture is on Warning Please read the instructions carefully They include important information about installation operation and maint...

Page 3: ...till require unit to unit connection by proper DMX cables Caution Common microphone cables may be used to connect small numbers of DMX fixtures over short distances but offer the risk of erratic operation Use of correct DMX cables greatly reduces data errors caused by improper connection If you are using a controller with 5 pin DMX output use a 5 pin to 3 pin adapter cable Connect fixtures togethe...

Page 4: ...run the chase the fixtures in the chain will set the series DMX address automatically Each lighting fixture needs to have an address set when in DMX mode to receive the data sent by the controller The address number is between 0 511 usually 0 1 are equal to 1 Please refer to the following diagram to set the address for the first four units The numbers 1 5 9 and 13 indicate the starting address of ...

Page 5: ...on DMX Channel Values 3 Channel Mode DMX Channel Values 5 Channel Mode DMX Channel Values 7 Channel Mode For additional details about DMX operation please review Section 10 8 IR Remote Control 8 1 IR Remote Control Keypad ...

Page 6: ...X polarity 3 If you have intermittent DMX signal problems check the pins on the cable connectors and on the fixture 4 Try to use a different DMX controller 5 Interference may occur if DMX cables are run alongside high voltage cables C Fixture responds erratically to DMX control 1 You may have a break in the DMX cabling Check the LED for the response of the master slave mode signal 2 Wrong DMX addr...

Page 7: ...acent incorrectly assigned fixture Multiple fixtures of the same type that use an identical starting address will function in unison Fixtures assigned properly spaced starting addresses will operate individually but a DMX controller with sufficient channels can be configured to run these same fixtures either combined or independently The sequence in which DMX fixtures are connected has no effect o...

Reviews: