background image

FLASk CLAMPS

 

 

P

latforM

 

P

art

  

D

esCriPtion

 

M

aterial

 

C

aPaCity

 

n

uMber

10mL Erlenmeyer Flask Clamp 

stainless steel 

35 

980078

25mL Erlenmeyer Flask Clamp 

stainless steel 

20 

980079

50mL Erlenmeyer Flask Clamp 

stainless steel 

15 

980080

125mL Erlenmeyer Flask Clamp 

stainless steel 

12 

980081

250mL Erlenmeyer Flask Clamp 

stainless steel 

980082

500mL Erlenmeyer Flask Clamp 

stainless steel 

980083

500mL Media Bottle Clamp 

stainless steel 

980092

125mL Erlenmeyer Flask Clamp 

PVC 

12 

980428

250mL Erlenmeyer Flask Clamp 

PVC 

980429

500mL Erlenmeyer Flask Clamp 

PVC 

980430

a

CCessories

tESt tuBE rACkS

 

t

ube

 

P

latforM

 

P

art

  

D

esCriPtion

 

C

aPaCity

 

C

aPaCity

 

n

uMber

10 to 13mm Test Tube Rack 

63 

980193

14 to 16mm Test Tube Rack 

48 

980194

18 to 20mm Test Tube Rack 

35 

980195

22 to 25mm Test Tube Rack 

24 

980196

15mL Centrifuge Tube Rack 

42 

980198

50mL Centrifuge Tube Rack 

12 

980199

1.5 to 2mL Micro-Tube Rack 

70 

980191

installation of Flask Clamps - orbital Shaker
1.  Unit should be in standby mode.
2.  Remove non-skid rubber mat.
3.  Line up the hole(s) in the flask clamp to the hole(s) 

in the tray. Using the screw(s) provided, hand 
tighten into place using a flathead screwdriver.  
do not
 over tighten.

4.  Insert flask/media bottle into clamp and wrap the 

spring around the neck of the clamp to hold secure.

not for use with the Microplate Shaker.

installation of test tube racks - orbital Shaker
1.  Unit should be in standby mode.
2.  Remove non-skid rubber mat.
3.  Align the clip on the rack to the right side of the tray.
4.   Line up the holes in the test tube rack to the holes in the tray. Using the screws 

provided, hand tighten into place using a flathead screwdriver. do not over 
tighten.

installation of 1.5 to 2mL Micro-tube rack - Microplate Shaker
1.  Unit should be in standby mode.
2.   Align the Micro-Tube Rack side-to-side on the 

tray.

3.   Press the Micro-Tube Rack in place, you will 

hear the Micro-Tube Rack clip into position. No 
mounting screws are required.

13

Summary of Contents for 1000-3

Page 1: ...Instruction Manual Advanced 1000 3 Orbital Shaker Advanced 1000MP Microplate Shaker...

Page 2: ...___ Supplier ____________________________________________________________ Table of Contents Package Contents 1 Warranty 1 Installation 2 Maintenance Servicing 2 Equipment Disposal 2 Environmental Cond...

Page 3: ...gent or solvent on the front panel which is abrasive or harmful to plastics nor one which is flammable Always ensure the power is disconnected from the unit prior to any cleaning If the unit ever requ...

Page 4: ...immerse the unit for cleaning Do not operate the unit if it shows signs of electrical or mechanical damage Earth Ground Protective Conductor Terminal Alternating Current Henry Troemner LLC hereby dec...

Page 5: ...again be in standby mode B Speed display Displays the speed of the shaker C Up down arrows for set point control On off button starts stops shaking function D The speed indicator light will be illumin...

Page 6: ...mm x 20mm 5 amp quick acting Speed range 100 to 1200rpm Speed accuracy 2 Timer 1 second to 9999 minutes increased in 1 second increments Orbit 0 125 3mm Maximum weight capacity 8lbs 3 6kg up to 1000rp...

Page 7: ...for use with flask media bottle clamps or test tube racks See below for tray configurations Advanced 1000 3 Orbital Shaker Tray Configurations 35 10mL Erlenmeyer Flask Clamps 20 25mL Erlenmeyer Flask...

Page 8: ...ts Fuses 5mm x 20mm 5 amp quick acting Speed range 100 to 1200rpm Speed accuracy 2 Timer 1 second to 9999 minutes increased in 1 second increments Orbit 0 125 3mm Capacity 4 microplates or 2 micro tub...

Page 9: ...1 Place two 2 microplates or deep well blocks diagonally on the tray or place four 4 microplates or deep well blocks on the tray The plates blocks do not have to be filled 2 Place the corner of the p...

Page 10: ...dicate the previous set time b Simultaneously press both the up and down arrows the display will indicate zero 0 00 The unit time is now set to zero 0 00 minutes Alternately you can use the up down ar...

Page 11: ...exceeded loose foot suction cup Press the standby button to clear this error Be sure the load is within the maximum load capacity before restarting the unit If the E04 error persists switch the unit o...

Page 12: ...385703 00 2 Tray 580050 00 3 Display board 380780 00 4 Belt 580019 00 5 Motor 380712 00 6 Motor transition board 380415 00 7 Connection cable 380720 00 8 IEC power entry module 386122 00 9 Feet sucti...

Page 13: ...5702 00 2 Tray assembly 880761 00 3 Display board 380780 00 4 Belt 580019 00 5 Motor 380712 00 6 Motor transition board 380415 00 7 Connection cable 380720 00 8 IEC power entry module 386122 00 9 Feet...

Page 14: ...2 980199 1 5 to 2mL Micro Tube Rack 70 2 980191 Installation of Flask Clamps Orbital Shaker 1 Unit should be in standby mode 2 Remove non skid rubber mat 3 Line up the hole s in the flask clamp to th...

Page 15: ...Universal Harness Platform Part Description Microplate Capacity Capacity Number Universal Harness 2 or 4 1 980192 Installation of 2 Bar Adjustable Platform Orbital Shaker 1 Unit should be in standby...

Page 16: ...201 Wolf Drive PO Box 87 Thorofare NJ 08086 Phone 1 888 TALBOYS Fax 856 686 1601 E mail troemner troemner com www troemner com 715082 00 REV 6 5 15 Manufactured by...