Assembly instructions
Troubleshooting
24 / 27
Rotary indexer RTX
Version 1.0
8
Troubleshooting
Fault
Possible cause
Remedy
Drive does not turn
•
No supply voltage
•
Drive contactor malfunction
•
Drive protection switch has
triggered
•
Brake not released
•
Check power supply
•
Change contactor
•
Let the drive cool down; latch the drive
protection switch
•
Incorrectly connected or worn brake
•
Check sensor setting on position cam
•
Check sensor cable on sensor
The drive turns but the rotary
indexer does not turn and the
roll star / output flange has
no clearance
•
Worm gear malfunction
•
Safety clutch overload / disengaged
•
Input shaft is broken
•
Clamping set not mounted correctly
•
Contact TAKTOMAT GmbH
•
Remove the external blockage /
engage the safety clutch
•
Contact TAKTOMAT GmbH
•
Install clamping set according to
manufacturer's operating instructions
The drive turns but the rotary
indexer does not turn and the
roll star / output flange has
clearance
•
Cam follower ripped off by large
overload
•
Contact TAKTOMAT GmbH
Drive turns with loud
humming noises
•
Drive operates on 2 phases only
•
Check fuses or drive contactor
•
Measure current in all 3 phases
(voltage measurement is not enough)
Sensor transmits no signal
•
Sensor not actuated / not fully
actuated
•
Cable defective
•
Sensor defective
•
No supply voltage
•
Remove blockage
•
•
Check cable and replace if necessary
•
Replace sensor
•
Check power supply