background image

1) Select the mounting location and position of sensor 

(wall mount or overhead mount).

Place the unit body on the mounting location and undermark 

the screw hole and wiring hole.

Run wires through the wiring ditch and insert 

to  the  wiring  holes  on  the  left  side  of  the 

terminal unit.

The  terminals  accept  from  AWG  14  up  to 

AWG 22.

Connect attached resistor (82

Ω

, 3W) in series 

with  the  power  input  when  supply  voltage  is 

20 to 24VAC.  

The NC and NO output will reverse according 

to the "relay mode" set up.

  (See 6 for explanation)

The unit is intended to be powered by either a 

UL Listed power supply or a UL Listed Class 

2 transformer.

Pull wires through the wiring hole and mount the unit body 

with the tapping screws provided.

4

INSTALLATION

5

WIRING

2) Separate the cover from the sensor unit.

3) Drill the mounting hole.

4) Mount the base.

To lock the cover, pierce the cover locking screw hole.

Insert cover locking screw and tighten.

This is necessary for all UL installations.

5) Securing the cover

Wall mount

Mount the unit in the center of door.

Thumb

Forefinger

Push the window.

Place finger on the knockout

and pull this side to detach

the cover.  It will come off

easily.

Overhead mount

[TERMINAL ARRANGEMENT]

2.5" (64mm) or more

mounting depth

1 2 3 4 5 6 7 8

12 to 24V DC/

AC(50/60Hz)

40mA MAX./DC

70mA MAX./AC

N.C. COM. N.O.

( ):RELAY MODE B

DRY CONTACT RELAY 2c

30VDC 1A / 24VAC 0.6A

(N.O.)

(N.C.)

N.C. COM. N.O.

(N.O.)

(N.C.)

FOR 20 to  24V AC

REFER Instr.Doc.

04-999 Rev.1506