Takex PA-6614E Instruction Manual Download Page 4

No.06-073   C0055

,Q-DSDQ

Takex America Inc.

Takenaka Engineering Co., Ltd.

KWWSVZZZWDNH[HQJFRMS

Takex America Inc.

KWWSVZZZWDNH[FRP

Takex Europe Ltd.

KWWSVZZZWDNH[FRP

,QWKH86

,QWKH8.

,Q$XVWUDOLD

$YLDU\&RXUW:DGH5RDG
%DVLDPSVKLUH5*3(8.
7HO
)D[

+RZOH\V5RDGLOO
9,&
7HO
)D[
KWWSVZZZWDNH[FRP

*RMR'RUL6RWRNDQ1LJDVKLQR
<DPDVKLQDNX.\RWR-DSDQ
7HO
)D[

6DQ=HQR:$<
6XQQ\YDOH&$86$
7HO
)D[

Limited Warranty :

TAKEX products are warranted to be free from defects in material and workmanship for 12 months from original date of shipment. Our warranty does not cover damage or 
failure caused by Acts of God (including inductive surge by lightning), abuse, misuse, abnormal usage, faulty installation, improper maintenance or any repairs other than 
those provided by TAKEX. All implied warranties with respect to TAKEX, including implied warranties for merchantability and implied warranties for fitness, are limited in 
duration to 12 months from original date of shipment. During the Warranty Period, TAKEX will repair or replace, at its sole option, free of charge, any defective parts 
returned prepaid. Please provide the model number of the products, original date of shipment and nature of difficulty being experienced. There will be charges rendered for 
product repairs made after our Warranty period has expired.

■OPTION:BL-5000

:BCW-401
:BP-150AE

7528%/(6+227,1*

(;7(51$/',0(16,216

63(&,),&$7,216

Solve possible problems according to the following table. If normal operations cannot be 
restored by this means, contact either the dealer from whom you bought the unit or TAKEX.

Completely inactive

Sometimes inactive

(1)No power supply, broken wire or improper voltage.

(2)Not yet 1 minute after power turned on (Alarm LED is flickering.)

(3)Cover shielded by substances (including glass).

(4)Improper area adjustment.

(1)Improper area adjustment.

(2)Cover face is soiled with dust or water drop.

(3)Is the protection range proper ?

(4)Small temperature difference between people and back ground.

(1)Something moving in protected area or too rapid temperature variations.

(3)Intense reflection of sun light or head light shining on the sensor.

(4)Is the sensor reacting to passersby outside ?

(1)Poor contact output connection or broken wire or short circuit.

(2)Contact output is not working.

(3)Is the connected unit operation nomal ?

(1)Correct power supply or replace broken wire.

(2)Allow for warming up time (about 1 min.)

(3)Remove the substances.

(4)Readjust the protection area setting.

(1)Readjust the protection area setting.

(3)Reposition so that the range is proper.

(4)Set sensitivity 120%

(1)Remove the cause.

(2)Relocate device.

(3)Relocate device. Shield with a blind.

(4)Readjust the protection area.

(1)Check the wiring or connection.

(1)Check for disconnection or damage inside the device.

(2)Check the contact output terminal using a tester. 

(3)Check the connected unit. 

Mounting position

Ambient temperature range

Memory LED

Sensitive zone

Supply voltage

Coverage

Detection system

Model

Tapping screw : 2 pcs.    Sensor locking screw : 1 pce.

PA-6614E  

PA-6614E(BL)  

The specifications are subject to change without notice.

(2)Clean the cover with soft cloth. 
    (Do not use chemicals such as thinners or alcohol.)

Activated when no person 
has passed

The alarm LED lights, but 
connected units are inactive

(2)Large electrical noise source such as power machine nearby or
     its wiring close to that of sensor.

Trouble

Check

Corrective Action

Passive infrared  (Twin mirror)

Wide angle 14m Max.

8mA Max.

38 pairs

7 to 30V DC (non-polarity)

Dry  contact (Semi-Conductor)
 (N.C. / N.O. selectable)
Reset : Approx. 2 sec., 24V (AC/DC) 0.25A
(protective resistor 3.3

Ω

)

3 minutes flashing, 47 minutes lighting and 
automatically reset.  (ON/OFF selectable)

Red   : Flashing at warming up

            Lighting at alarm (LED can be disabled)

Yellow   : Flashing at memory activated

                Lighting at memory indication

Vertically : 23°
Horizontally : 25°

   (on mounting hole of base)

60% / 80% / 100% / 120%  changeover  

-15

to +55

(+5° F to +131° F) without condensation

Indoor ceiling
 (wall mount with optional attachment BCW-401)

Accessory

Terminals on separate base unit

120g  (4.23oz)

Body /Cover : White resin 

Body /Cover : Black resin 

Protection

Sensor unit

Base unit

φ120mm(φ4.72")

Wire hole

35

35゜

35゜

35

°

  R15mm
(R0.59")

Release lever

Locking

screw hole

φ98.5mm(φ3.88")

55mm(2.17")

8mm(0.31")

φ83.5mm(φ3.29")

66.7mm(2.60")

 5-φ4.2mm

(φ0.17")

φ9mm
(φ0.35")

4.2mm(0.17")

34mm (1.34")

   

10.5mm

(0.41"

)

The alarm LED lights and 
alarm signal output 
continuously

(1)Self-diagnosis error.

Current consumption

Alarm signal

Alarm memory

Alarm LED

Adjustment

Sensitivity changeover

 Self-diagnosis function

 Temperature compensate 

Other functions

N.C.    30V(AC/DC)0.25A

Wiring connection

Weight

Appearance

Tamper