Takex PA-6612E Instruction Manual Download Page 2

4

INSTALLATION

3

DO'S AND DON'T'S

5

WIRING

Install the sensor in a location 
such that intruders are more likely 
to cross the protection zones, 
rather than approach head on.

Do not install in a site which 
is subject to electrical noise or 
intense vibration.

Avoid direct sunlight, spot light or 
intense reflections on the sensor or 
the protection zone.

Do not install the sensor outdoors 
(indoor only).

[MAINTENANCE]

1.When the unit is soiled, clean the cover with a soft cloth   

moistened with a small amount of cleansing -solution.  Do not   
use chemicals such as thinners or alcohol.

2.Check operation once a week.  Do not fail to check operation   

whenever furniture in coverage area is moved.

The passive infrared sensor is designed to detect infrared energy 
variations caused by the presence of a human body.  Therefore, 
note that similar variations in conditions in protection area, due 
to other reasons, may cause the sensor to create an alarm as it is 
unable to distinguish between sources.

(1) Slide release lever 

to a direction that 
an arrow points to 
detach sensor unit 
from base unit.

(2) Mount the base on the ceiling with screws.  

Fix so that the front mark (   ) is pointing to 
the center of  protection area.

Break knockout 
and put the wire 
through wire 
lead on base 
unit, when 
exposed wiring.

(3) Connect the wires to the terminals referring 

to the paragraph on WIRING.

(4) Set the protection area referring to the 

paragraph on PATTERN SETTING.

(5) Match up a front 

mark on base unit 
with that on 
sensor unit.

Put a sensor unit 
into a base unit 
from front mark 
side.

Push sensor unit until release lever will 
clicks.

Basic connection

[When two units are used]

Allowable wiring distance between sensor and power source

     Size of wire used

AWG 22 (Dia. 0.65mm)

AWG 20 (Dia. 0.80mm)

AWG 18 (Dia. 1.00mm)

Distance at 12VDC

    820 ft. (250m)

  1476 ft. (450m)

  2296 ft. (700m)

Note 1) The maximum wire length, when two or more units are connected, is 

the  above distance divided by the number of units.

        2) The protection circuit can be wired to a distance of 3,280 ft (1,000m) 

with AWG 22 (0.65mm dia.) wire.

Allow approx. one minute for warm-up after power is applied.  (Alarm 
LED is flashing)  In the meantime, an alarm is not initiated.

After the one minute has passed the unit will be in the armed condition 
and will trigger when detecting a human body.

All wiring should be in accordance with the national electric code NFPA-70. 

Power

Signal

input


Sensor (N.C.)

1

2 3

4

1

2 3

4

Sensor (N.C.)

(6) When sensor unit is detached, hold 

it and slide release lever as 
illustrated.

(7) When sensor unit is locked, 

tighten the locking screw. 

Sensor locking screw

Release lever

Terminal 

    arrangement

1

2

3

4

7

Alarm output
Dry contact (Semi-Conductor) 
N.C.  N.O. changeover
Reset : approx. 2 sec.
24V (AC/DC) 0.25A
(Protective resistor 3.3

Ω

)

Power (non-polarity)
10.5

28V DC

25mA or less
(+2mA at L/C use)

Tamper
N.C.
30V(AC/DC)
0.25A

L/C 

LED

Control

6

5

The power supply used with this unit 
must have a minimum 4 hours 
stand-by power capbillity.