Takex PA-480S Instruction Manual Download Page 4

9

SPECIFICATIONS

10

EXTERNAL DIMENSIONS

                  

         

Unit: inch (mm)

■Option : Ceiling/Wall mounting attachment : BCW-401

Limited Warranty :

TAKEX products are warranted to be free from defects in material and workmanship for 12 months from original date of shipment. Our warranty does not cover 
damage or failure caused by natural disasters, abuse, misuse, abnormal usage, faulty installation, improper maintenance or any repairs other than those provided 
by TAKEX. All implied warranties with respect to TAKEX, including implied warranties for merchantability and implied warranties for fitness, are limited in 
duration to 12 months from original date of shipment. During the Warranty Period, TAKEX will repair or replace, at its sole option, free of charge, any defective 
parts returned prepaid. Please provide the model number of the products, original date of shipment and nature of difficulty being experienced. There will be 
charges rendered for product repairs made after our Warranty Period has expired.

In Japan

Takex America Inc.

4/15 Howleys Road, Notting Hill,
VIC, 3168
Tel  : +61 (03) 9544-2477
Fax : +61 (03) 9543-2342

Takenaka Engineering Co., Ltd.

83-1, Gojo-sotokan, 
Higashino, Yamashina-ku, 
Kyoto 607-8156, Japan 
Tel  : 81-75-501-6651
Fax : 81-75-593-3816
http : // www. takex-eng. co. jp /

Takex America Inc.

3350, Montgomery Drive,
Santa Clara, 
CA 95054, U.S.A
Tel  : 408-747-0100
Fax : 408-734-1100
http : // www. takex. com

Takex Europe Ltd.

Takex House, Aviary Court, Wade Road,
Basingstoke, Hampshire. RG24 8PE, U.K.
Tel  : (+44) 01256-475555
Fax : (+44) 01256-466268
http : // www. takexeurope. com

In the U.S.

In the U.K.

In Australia

COVER LOCKING SCREW

WIRING HOLE

1.44”(36.5)

3.74”(95)

3”(76)

3.29”(83.5)

3.54”(90)

5”(127)

2.43”(62.5)

φ0.16 (φ

4) 

HOLE

TROUBLESHOOTING

8

Completely inactive

Trouble

Check

Corrective Action

Sometimes inactive

Activated when 
no person has passed

Alarm LED lights, 
but connected devices
are inactives

(1) Connect wiring correctly, or repair problem wire.
(2) Check connected devises.

Alarm LED continues lighting 
and alarm output doesn’t stop. 
(Abnormal detection)

(1) Unstable power supply voltage.

(1) Supply appropriate power voltage.

(1) Improper detection area settings (including detection distance).
(2) Improper function mode setting.
(3) Detection lens is covered with dust or water droplets.

(1) Readjust detection area.
(2) Readjust mode setting.
(3) Clean the lens with soft and dry cloth.

(1) Unstable power supply voltage.
(2) Something is moving within the detection area, or there are sudden 

changes in temperature.

(3) A source of electrical noise (broadcasting station, amateur radio station, 
      etc.) is nearby.
(4) Strong light (direct or reflected) such as sunlight or headlights from 

front side of the detection area.

(5) Detecting someone passing outside the detection area.
(6) There are many charges in temperature in detection area.
(7) Movement of pets is detected.
(8) Movement of robot cleaners is detected. 

(1) Supply appropriate power voltage.
(2) Remove problem object.

(3) Change mounting location.

(4) Change mounting location or shield light with blinds, etc.

(5) Readjust detection area.
(6) Set signal count to "4". 
(7) Prevent pets from entering detection area.
(8) Prevent robot cleaners from entering detection area.

(1) Power supply is not connected (including broken wiring).
(2) Power supply voltage is low.
(3) 1 minute has not passed yet since turning the power ON.
(4) The detection area is blocked by obstacles (which may include glass).
(5) Improper detection (including detection distance).
(6) Improper function mode setting.

(1) Check the power wiring. 
(2) Supply appropriate power voltage.
(3) Wait approximately 1 minute.
(4) Remove obstacles.
(5) Readjust detection area.
(6) Readjust mode setting.

MAINTENANCE

Analyze possible problems according to the following table. If normal operations cannot be restored by 
these means, contact either the dealer from whom you bought the unit or TAKEX.

To clean the device, use a soft, wet cloth and then wipe off any water drops. If the device is particularly dirty, dip the soft cloth in the water that contains a weak 
neutral detergent. Wipe the device gently with the cloth, then wipe off any detergent that remains.  Do not use substances such as thinner or benzene. 
(The plastic parts may deform, discolor or change their properties.)
Perform operation checks on a regular basis.

(1) Wiring failure, broken wire, or short-circuit.
(2) Connected devices don’t function normally.

Specifications and design are subject to change without

 prior notice.

Model
Detection System
Coverage
Sensitive zone
Area adjustment
Supply Voltage
Current consumption

Alarm output

Tamper output

LED(Red)

Trouble signal

Ambient 
temperature range

Mounting position

Wiring connections
Weight
Appearance

PA-480S

        Passive infrared  (Twin element

Pulse count) 

Super Wide angle radius    26.3

ʼ

 (8m) 

64 (32pairs) 

Downward  5  positions

9.5 to 28V DC

non-polarity

20mA Max.

Dry contact  N.C.  (Semi-conductor)
Reset : Apporox, 2 sec.
30V DC (24V AC) 0.25A Max.   (protective resistor 3.3

Ω

)

Dry contact  N.C.
Open when cover is detached
30V DC   0.1A MAX.  (protective resistor 3.3

Ω

)

Alarm LED  Flickering (every 0.5 sec.)  : Warming-up 
Lighting (approx. 2 sec.)   : Alarm 
Flickering (every 2 sec.)   : Trouble indication
Continuous lighting           : Trouble alarm
Unit trouble : Monitorring inner circuit and wiring damage

Operation : Trouble alarm

Low voltage trouble  : Monitoring low voltage

Operation : Trouble alarm 

+14°F to +122°F  (without dewdrops)

(

10

 to 

50

)

Indoor (Wall/pillar) 

     Ceiling mount is possible with optional attachment

Terminals

5.82oz (165g)
resin (White)

2021.8.26