background image

PARTS DESCRIPTION

1

PRECAUTIONS

2

Warning

Caution

This mark indicates details regarding handling which, if ignored, may result in death or injury.

This mark indicates points of which the user should be aware.

This mark indicates a prohibition, with the item shown in 
the mark specifically prohibited.

This mark indicates details regarding handling which, if ignored, may result in delays in reporting 
attributable to false or missed alarms.

Example: 

Disassembly prohibited

Ensure that you do not disassemble or alter this 
product, as this may lead to fire, electric shock, or 
damage.
In the event of an abnormal condition such as smoke 
or unusual smells or sounds being emitted, 
immediately stop power supply to the device, confirm 
that smoke is no longer being emitted, and request 
repair from the retailer. Continuing to use the sensor 
in this condition may lead to fire or electric shock.

Do not use the sensor with voltages other than as 
specified (9 to 28V DC). Doing so may cause fire or 
electric shock.

In the event of water entering the sensor, immediately 
stop power supply to the device, and contact the retailer. 
Continuing to use the sensor in this condition may lead 
to fire or electric shock.

Ensure that the sensor is mounted in a strong location 
such as over a reinforcing beam on the wall. When 
mounting on surfaces other than wood such as 
plasterboard or concrete, ensure that the sensor is 
securely affixed using anchors and screws suited to the 
surface material. If the sensor should fall off, this could 
result in injury or damage.

Do not connect devices that exceed the capacitance as 
shown on the output terminal. Doing so may cause 
fire.

Do not use the sensor in bathrooms or other locations 
with high humidity. Doing so may cause fire or electric 
shock.

Tamper switch

PARTS

Cover

Body

Accessory

Area masking sheet (4set)

Self tapping screw 
(

φ

4x35)2 pcs

Instruction Manual

Operation LED

Mode
setting 
switches

Cover locking screw

Lens

Wiring hole

Holder locking screw

Adjustment index

Adjustment holder

Terminal

Sensitivity 
adjustment

Back tamper rubber

1-1

1-2

1-3

OPERATIONAL PARTS TITLES AND FUNCTIONS

Sensitivity adjustment  : Dial to adjust detection sensitivity
Mode setting switches : Indicator LED, contact logic, pulse count, and area selection DIP switches
Adjustment holder        : Part to adjust detection distance

Warning

Description of the Display

[

7-2

 Installation Method]

s

The following marks indicate precautions that should be adhered to in order that this 

  product can be used safely. These are important; therefore ensure that you read these 
  carefully.

Pole mounting bracket knockout 
(use for pole mounting option)

[

7-2

 Installation Method]

[

7-2

 Installation Method]

[

3-2

 Area Adjustment]

[

3-2

 Area Adjustment]

[

3-2

 Area Adjustment]

[

4

 FUNCTION]

[

4

 FUNCTION]

[

5

 SETTING]

[

5

 SETTING]

[

3

 DETECTION AREA]

[

7-2

 INSTALLATION METHOD]

[

3-3

 AREA MASKING]

[

6

 WIRING]

[

6

 

WIRING]

Wall mounting knockout

Wall mounting knockout

[

7-2

 Installation Method]

[

7

 INSTALLATION]

[

4

 FUNCTION]

[

5

 SETTING]

[

5

 SETTING]

Pole mounting bracket 
knockout
 (use for pole mounting option)

s4HISEXPLAINSTHECONTENTOFTHEPACKAGINGASWELLASPARTNAMESANDFUNCTIONSASDETAILEDINTHISDOCUMENT

  Please confirm that the sensor and all parts are included in the packaging.

Summary of Contents for OMS-12FE

Page 1: ...bber enables detection of interference with the sensor such as attempts to remove it from the mounting surface 7 INSTALLATION 5 Support for mounting on poles optional pole attachment Use of the option...

Page 2: ...uld result in injury or damage Do not connect devices that exceed the capacitance as shown on the output terminal Doing so may cause fire Do not use the sensor in bathrooms or other locations with hig...

Page 3: ...difference Install the unit at the height of g M TO g M FROM the ground Do not install the unit by an air conditioning exhaust vent Remove all obstructions TREES CLOTHESLINES ETC Do not install the se...

Page 4: ...stance When using at 12m distance 3 3 1m 3 3 1m 3 3 1m 3 3 1m 33 10m 40 12m 0 16 5 5m 33 10m 40 12m 0 16 5 5m 33 10m 40 12m 0 16 5 5m 33 10m 40 12m 0 16 5 5m 33 10m 40 12m 0 16 5 5m 3 3 1m 15 3 16 5 5...

Page 5: ...Reference diagram for masking Bend the sheet to form a semicircle and fit inside of the cover s lens holder then insert the cutout portion of the sheet into the tabs on the lens holder Mount so that...

Page 6: ...ver installation procedure Move the knockout tab on the rear of the sensor left and right and twist off Attach the back tamper rubber Take care with the mounting direction Additionally after attachmen...

Page 7: ...be adjusted in accordance with the environment and intended purpose Normally use medium 100 Setting the sensitivity to 170 will trigger detection even at small changes in temperature Use this in stabl...

Page 8: ...f the outside and inside sensor knockouts to use then feed the wiring through the wiring hole and connect to the terminals For external wiring Wiring from above Wiring from below Wiring hole Wiring bo...

Page 9: ...35mm 2 Mounting pitch 7 56 197mm Pole mounting bracket 2 Pole mounting bracket screws 4 3 Place the optional fixing bracket around the pole and fix the sensor to the pole with the pole bracket and sc...

Page 10: ...water droplets 3 Unsuitable detection or pulse count settings 1 Readjust detection area 3 DETECTION AREA 2 After wiping with a damp soft cloth wipe off water droplets 3 Ensure appropriate detection a...

Page 11: ...in 9 to 28V DC non polarity 20mA MAX Dry contact relay output N C N O selectable Contact capacity 30V AC DC 0 2A MAX Resistive load Contact operation Detection time 2sec Dry contact relay output N C C...

Page 12: ...eng co jp Takex America Inc 230E Caribbean Drive Sunnyvale CA 94086 U S A Tel 408 747 0100 Fax 408 734 1100 http www takex com Takex Europe Ltd Takex House Aviary Court Wade Road Basingstoke Hampshire...