When two or more sets are used, two frequencies (L and H types) should be used in order 

to avoid cross talk or interference.  Refer to the following  example.

H type should be used for TR3 and RE3 when TR1 and RE1 are L type.

Do not install the transmitter and 

the receiver at a same corner. 

Microwave sensor with the same 

frequency can be used for this case.

Mounting

3) Wall mount 

4) Pole mount 

5) Pole mounting back to back. 

Make holes in the wall.

Place the mounting plate the wall as a template for drilling 

and mark the screw holes. (Allow a space of  1" (25mm) 

above and below the plate.

This will provide easy detachment of the cover after 

installation.)

Install the sensor.

Insert tapping screws to 0.59" (15mm) under the screw head.

Install the mounting plate on the 

wall after pulling the wire 

through it.

Connect terminals.

Attach cover.

Install sensor on the pole.

Attach the U brackets to pole and fix the mounting plate 

with screws.

Fix the sensor the body to the mounting plate.

Connect the terminals.

Attach the sensor and pole covers.

 (Break the knockouts on the cover 

and pole cover to adapt to pole's 

diameter and configuration.)

Attach the two U brackets to 

the poles, one on top of the 

other, facing opposite 

directions. 

    (See illustration.)

Make a wiring hole in the pole. Pull 

through wire. 

2) Turn the anntenna of 

each unit by 90 degrees 

right or left.  

Then loosen the screws 

(2 places) to remove the 

mounting plate from 

the body.

1) Detach cover with a screw driver.

Wood

φ

0.12"

 (

φ

3mm)

Concrete

Use plug etc.

Installation example

Linear protection (long distance) 

Perimeter protection

1.38" (35mm) or more

1" (25mm) or more

0.59" (15

mm)

The grommet is compatible with a wire of 

φ

0.12" (

φ

3mm) 

to 

φ

0.24" (

φ

6mm) outer diameter. 

   When a wire of more than 

φ

0.24" 

(

φ

6mm) outer dia. is used, cut 

off the dotted line portion as 

illustrated   using pliers or the 

like. Then use caulking to 

prevent insects from entering 

into unit. 

Grommet

4

INSTALLATION

Pre-drill in wall.

    Concrete wall : Refer to specifications of the securing plug used.

    Wooden wall : 0.12" (3mm) diameter.

TR1

TR

TR

TR

TR

TR3

TR2

RE2

(L type)

(L type)

(H type)

330' (100m)

330' (100m)

330' (100m)

1' (0.3m)

1'

 to 

16.5'

(0.3m

 to 

5m)

RE1

RE3

RE

RE

RE

RE

(Ex. 1)

(Ex. 2)

(Ex. 3)

Protected

site

Do not use different frequencies (H and L) in a detection line.

Use a pair of same frequency : TR(H) and RE(H) OR TR(L) and RE(L).

Do not stack the sensors vertically.

(Top view)

(Top view)

±90°

±10°

90°

90°

(Option)

Knockout

φ1.77" (φ45mm)
φ1.50" (φ38mm)