When two or more sets are used, two frequencies (L and H types) should be used in order
to avoid cross talk or interference. Refer to the following example.
H type should be used for TR3 and RE3 when TR1 and RE1 are L type.
Do not install the transmitter and
the receiver at a same corner.
Microwave sensor with the same
frequency can be used for this case.
Mounting
3) Wall mount
4) Pole mount
5) Pole mounting back to back.
①
Make holes in the wall.
・
Place the mounting plate the wall as a template for drilling
and mark the screw holes. (Allow a space of 1" (25mm)
above and below the plate.
This will provide easy detachment of the cover after
installation.)
②
Install the sensor.
・
Insert tapping screws to 0.59" (15mm) under the screw head.
・
Install the mounting plate on the
wall after pulling the wire
through it.
・
Connect terminals.
・
Attach cover.
②
Install sensor on the pole.
・
Attach the U brackets to pole and fix the mounting plate
with screws.
・
Fix the sensor the body to the mounting plate.
・
Connect the terminals.
・
Attach the sensor and pole covers.
(Break the knockouts on the cover
and pole cover to adapt to pole's
diameter and configuration.)
・
Attach the two U brackets to
the poles, one on top of the
other, facing opposite
directions.
(See illustration.)
①
Make a wiring hole in the pole. Pull
through wire.
2) Turn the anntenna of
each unit by 90 degrees
right or left.
Then loosen the screws
(2 places) to remove the
mounting plate from
the body.
1) Detach cover with a screw driver.
Wood
φ
0.12"
(
φ
3mm)
Concrete
Use plug etc.
Installation example
●
Linear protection (long distance)
●
Perimeter protection
1.38" (35mm) or more
1" (25mm) or more
0.59" (15
mm)
*
The grommet is compatible with a wire of
φ
0.12" (
φ
3mm)
to
φ
0.24" (
φ
6mm) outer diameter.
When a wire of more than
φ
0.24"
(
φ
6mm) outer dia. is used, cut
off the dotted line portion as
illustrated using pliers or the
like. Then use caulking to
prevent insects from entering
into unit.
Grommet
4
INSTALLATION
・
Pre-drill in wall.
Concrete wall : Refer to specifications of the securing plug used.
Wooden wall : 0.12" (3mm) diameter.
TR1
TR
TR
TR
TR
TR3
TR2
RE2
(L type)
(L type)
(H type)
330' (100m)
330' (100m)
330' (100m)
1' (0.3m)
1'
to
16.5'
(0.3m
to
5m)
RE1
RE3
RE
RE
RE
RE
(Ex. 1)
(Ex. 2)
(Ex. 3)
Protected
site
・
Do not use different frequencies (H and L) in a detection line.
Use a pair of same frequency : TR(H) and RE(H) OR TR(L) and RE(L).
・
Do not stack the sensors vertically.
(Top view)
(Top view)
±90°
±10°
90°
90°
(Option)
Knockout
φ1.77" (φ45mm)
φ1.50" (φ38mm)