Takex F71R Manual Download Page 6

F71

Useful 8-unit detection

Optical transmission-type Anti

Interference feature

The Anti Interference feature prevents false operation
due to mutual interference even if up to 8 units are
installed adjacently.

Anti Interference for up to 4
sensors (response time: 250 

μ

s)

Anti Interference for up to 8 sensors
(response time: 500 

μ

s, turbo function

enabled)

Mutual interference 
prevented by optical transmission 
when more than one unit is adjacently installed.

Light transmitted

Light received

ON

OFF

ON

OFF

ON

OFF

Normal operation (NOR)

On delay (ON.D)

Off delay (OFF.D)

120%

Activation level

Received light level

Detection output

Stability output

Stability indicator

Flashes

Easy-to-understand stability function

When four consecutive detections with a received light level of
120% or lower of the activation level have occurred, the stability
output is activated.  At the same time, the stability indicator flashes
an alert.

Timer operation

A delay timer of about 40 ms is provided to allow for a
range of input conditions of the connected devices.
The timer is also useful for stabilization of detection output
such as canceling signal chattering.

Turbo function increases detecting distance

by 30%

When it is desirable to increase the detecting distance for
the current condition of use, enabling the turbo function
allows a distance increase of about 30%.

8

4

8

4

Up 30%

13

Fiber

o

ptic

sensors

Summary of Contents for F71R

Page 1: ...general purpose type NPN output F70AR F70AG F70AB F70AW PNP output F70ARPN F70AGPN F70ABPN F70AWPN Light source Red LED Green LED Blue LED White LED Output mode Open collector NPN PNP Model press pre...

Page 2: ...ctronic volume 8 The level of received light is indicated in 4 digit number Min 0 Max 1023 The example above shows that the current receive light level is 123 with reference to the activation level Le...

Page 3: ...l in high resolution provides highly accurate detection Wide dynamic range and high resolution are achieved at the same time High resolution is maintained even with a wide dynamic range The provided e...

Page 4: ...fluctuates due to dust or water drops Manual hysteresis setting feature The hysteresis can be arbitrarily set according to the application allowing setting of a small hysteresis for severe high accur...

Page 5: ...tion indicator is provided High speed response of 30 s H type sensor Variation Manual high performance model High accuracy 8 turn adjustment is equipped with a position indicator which allows direct r...

Page 6: ...light level Detection output Stability output Stability indicator Flashes Easy to understand stability function When four consecutive detections with a received light level of 120 or lower of the act...

Page 7: ...th straight M8 connector and 2 m cord Model FBC 4R2L equipped with angled M8 connector and 2 m cord Model FA7EU AC BF2 Description DIN rail mounting stopper Amplifier unit mounting bracket End unit Op...

Page 8: ...5 RH non condensing IP40 10 55 Hz 1 5 mm amplitude 2 hours each in 3 direction 500 m s2 3 times each in 3 directions Environment Environmental Specification Specification Light source wavelength Indic...

Reviews: