Takex F71 Series Manual Download Page 10

Detecting distance

35mm

95mm

Detection method

Reflective

Through-beam

Detection method

FR5BC

FT5BC

F71

Series

Detecting distance for -H type

For high-speed response models, the detecting distance is generally
about 30% of normal models.

(With turbo function disabled)

Typical example

Use the light shielding sticker (accessory) for grouping amplifiers
into blocks when taking advantage of the Anti Mutual
Interference features to use more than one sensor.  The sticker
can also be used when the transmission windows may be
subject to strong ambient light.  (If the detection allows no mutual
interference, there is no need to use the sticker even if the
amplifiers are mounted adjacently.)

8 sensors used (4 units of Block A and 4 units of Block B)

Apply one light shielding sticker to each of the open transmission windows in the
fourth and fifth units.

After the stickers have been applied, slide one block of units until they come in
contact with the other block.

Note: There may be interference between the two blocks of sensors.

Apply one light shielding sticker to each of the open transmission windows in the
eighth and ninth units.

After the stickers have been applied, slide one block of units until they come in
contact with the other block.

Note: There may be interference between the two blocks of sensors.

Apply one light shielding sticker to each of the open transmission windows in the

fourth and fifth units.

After the stickers have been applied, slide one block of units until they come in

contact with the other block.

Note: There may be interference between the two blocks of sensors.

The 4 units in Block A do not

interfere with each other

Selector switch = 4 (response

time = 250 

μ

s)

The 3 units in Block B do not

interfere with each other

Selector switch = 8

(response time = 500 

μ

s,

turbo function enabled)

The 4 units in Block B do not

interfere with each other

Selector switch = 4 (response

time = 250

μ

s)

The 8 units in Block A do not

interfere with each other

Selector switch = 8 

(response time = 500 

μ

s, turbo

function enabled)

The 2 units in Block B do not

interfere with each other

Selector switch = 8

(response time = 500 

μ

s,

turbo function enabled)

Example 1

7 sensors used (4 units of Block A and 3 units of Block B)

Example 2

10 sensors used (8 units of Block A and 2 units of Block B)

Example 3

8

7

6

5

4

3

2

1

Block B

Block A

Light shielding
sticker

The 4 units in Block A do not
interfere with each other
Selector switch = 4 
(response time = 250 

μ

s)

7

6

5

4

3

2

1

Block B

Block A

Light shielding
sticker

Block B

Block A

Light shielding
sticker

4

8

7

6

5

10

9

3

2

1

If the selector switch setting is mixed (both “4” and “8” settings are present)
within one block, the Anti Mutual Interference feature does not work.  Make sure
that the selector switch settings are consistent (either “4” or “8”) within one block.

For Correct Use

Be sure to follow the instructions in the operation manual provided for correct use of the product.

Summary of Contents for F71 Series

Page 1: ...ustment Position indicator is provided High speed response of 30 μs H type sensor Variation Manual high performance model High accuracy 8 turn adjustment is equipped with a position indicator which allows direct reading of the adjustment position F71series Manual setting Fiber optic sensors Type Manual setting general purpose type Manual setting high speed type NPN output F71R F71G F71B F71W F71RH...

Page 2: ...evel Received light level Detection output Stability output Stability indicator Flashes Easy to understand stability function When four consecutive detections with a received light level of 120 or lower of the activation level have occurred the stability output is activated At the same time the stability indicator flashes an alert Timer operation A delay timer of about 40 ms is provided to allow f...

Page 3: ...tor type also available Connection Model Type Amplifier main unit Fiber optic cable For different types and prices of fiber optic cables see pp 59 M8 connector type M8 connector connection type is separately available for all models For identification J follows the model number For connector specifications see p 23 Type of cords with M8 connector Model FBC 4R2S equipped with straight M8 connector ...

Page 4: ...h switch at 4 turbo function disabled 250 μs max With switch at 8 turbo function enabled 500 μs max 30 μs max 1 Rating performance Output mode Specification Light source wavelength Indicator Volume VR Switch SW Anti Mutual Interference Short circuit protection Material Connection Mass Accessory Operation indicator orange LED Stability STB indicator green LED SENS sensitivity adjustment volume 8 tu...

Page 5: ...F70BKPN F70WKPN Internal circuit Brown 12 24 VDC Black OUT PUT Blue 0V Internal circuit Brown 12 24 VDC Black OUT PUT Blue 0V Brown 12 24 VDC Pink external teaching Black OUT PUT Blue 0V Orange STB OUT Internal circuit Brown 12 24 VDC Pink external teaching Black OUT PUT Blue 0V Orange STB OUT Internal circuit Brown 12 24 VDC Black OUT PUT Blue 0V Orange STB OUT Internal circuit When not using ext...

Page 6: ... FBC 4R2S straight 2000 Color black 55 23 φ9 23 7 16 7 FBC 4R2L angled PNP output type F71RPN F71GPN F71BPN F71WPN F71RHPN F71GHPN F71BHPN F71WHPN Internal circuit Brown 12 24 VDC Black OUT PUT Blue 0V Orange STB OUT Internal circuit Brown 12 24 VDC Black OUT PUT Blue 0V Orange STB OUT 1 3 4 2 White Black Blue Brown N C unused Control output 0V 12 24 VDC F70A J 1 3 4 2 White Black Blue Brown Stabi...

Page 7: ... right and push in at the hinge Attachment Put the front hook of the amplifier on the rail or mounting bracket and press down the back of the amplifier Detachment While pressing the amplifier forward lift the front part and detach the front hook The cover opens up to the connector on the back and stays at the half opened position Pulling at the hinge with the cover half open allows removal of the ...

Page 8: ... power up Do not use the sensor in a place subject to steam large amount of dust or direct exposure to water or oil Do not use the sensor outdoors or in a place subject to direct disturbing light on the light receiving surface Use of a reflective type fiber optic cable at the maximum sensitivity may cause inadequate light blocking Be sure to use a work for sensitivity setting Attach the multi core...

Page 9: ...ame time as the activation of the stability output If the level of received light gains a margin the stability output is deactivated and the stability indicator stops flashing and becomes illuminated normal illumination Sensitivity adjustment Reflective type adjustment for Light ON mode Place the object to be detected in a given position turn up the sensitivity adjustment volume SENS gradually fro...

Page 10: ... the open transmission windows in the fourth and fifth units After the stickers have been applied slide one block of units until they come in contact with the other block Note There may be interference between the two blocks of sensors The 4 units in Block A do not interfere with each other Selector switch 4 response time 250 μs The 3 units in Block B do not interfere with each other Selector swit...

Page 11: ...Series F 71 Series Common M8 connector type For dimensions of connector cords see p 23 Receiver Transmitter 5 9 9 16 16 21 21 11 5 36 5 2 φ3 2 5 2 oval hole 2 φ3 2 hole Mounting bracket φ4 8 cord 2 m in length 3 4 7 4 8 4 60 3 30 For dimensions of fiber optic cables see pp 67 ...

Reviews: