30
6 Rockwell Connection
6.2 Parameter Settings
6.2
Parameter Settings
This section shows the parameter settings for Rockwell Connection in MES Interface Function Configuration Tool.
For details on MES Interface Function Configuration Tool, refer to the following:
MELSEC iQ-R MES Interface Module User's Manual (Application)
Access target device setting
The following shows the setting of an access target device accessed from an MES interface module.
Window
1.
Click "Target Device Settings" in the edit item tree.
2.
Click the [Edit] button in "Target Device Setting List".
Displayed items
*1 Refers to the TCP/IP port number (44818) for Ethernet/IP.
Precautions
The following items cannot be set.
• Multiple CPU Setting
• Co-Existence Network Route setting
• Global Label/Common Device Comment Settings (optional)
Item
Description
Device Type
Select "ROCKWELL(AB)".
MES Interface Module Setting
Port No.
Set the port number of an MES interface module (0, or 1024 to 65535).
If setting '0', a free port is automatically set.
AB-PLC Setting
IP Address
Set the IP address of an AB-PLC.
Port No.
The port number
of an AB-PLC is displayed.
CIP Port No.
Set the CIP port number of an AB-PLC (1 to 15).
CIP Link Address
Set the CIP link address of an AB-PLC (0 to 255).
CPU Type
The CPU type of a connection target AB-PLC is displayed.
Connection Timeout Multiplier
Select a multiplier.
A timeout time is calculated by multiplying an interval set for "Requested Packet
Interval : RPI (ms)" by a multiplier selected for this item.
Requested Packet Interval : RPI
(ms)
Set an interval to connect to an Ethernet/IP-supported device (0 to 2147483647
milliseconds).