About this machine
10
Rear Panel
30
21
22
23
24 25
26 27
28
31
29
32
*1000V type is unimplemented
㉑
. ISOLATED CONTROL
Isolated Control Connector
This is the Status/Alarm Output Connector.
It is used for external analog control input of isolation type,
analog monitor output, and contact input when the isolation
analog option is mounted,
Use the included specialized connectors.
㉒
. SERIES CONTROL
Series Operation Control Connector
Connector for series connections.
When using in the slave mode, connect with the Master unit’s
minus output terminal using wires.
㉓
. EXTERNAL CONTROL
External Control Connector
Connectors for external analog control input and analog monitor
output.
Use the included specialized connectors.
㉔
. M/B CONTROL (IN)
Parallel Operation Control (Input) Connector
Control Signal Input Connector for parallel operations.
㉕
. M/B CONTROL (OUT)
Parallel Operation Control (Output) Connector
Control Signal Output Connector for parallel operations.
㉖
. TERMINATION
Termination Resistor ON/OFF Switch
When controlling one unit of this product via serial port, please
set the termination toggle switch to ON.
When using 2 or more power supplies, please set the first and
last units’ termination resistor ON/OFF switch to ON (set other
units' ones to OFF).
㉗
. SERIAL I/F 2
Serial Port/Multi-Channel Connectors
Connectors for when controlling multiple HX-S-G2 Series
units or for controlling RS-485 type, serial ports.
Connected with special cable. (T485-****: * is the code that
indicates length.)
㉘
. SERIAL I/F 1
Serial Port Connector
Connector for connecting computers etc. with serial cables
(RS-232C).
㉙
. LINE INPUT
Input Terminal Platform
This is the terminal platform that connects the power of this
product
㉚
. Ventilation Discharge Opening
Ventilation discharge opening for cooling the
product internally.
㉛
. M/B FG
FG terminal for parallel connection cable
This is the terminal for connecting the FG of parallel
connection cable.
㉜
.
PROTECTIVE EARTH TERMINAL (M6)
As for parallel connection cables, be sure to use the
special cable (HXPH-****:*specifies the length).
!
WARNING
Mandat ory
Summary of Contents for HX-S-G2 Series
Page 165: ...Special Loads 165 This page is blank...
Page 169: ...Maintenance 169 This page is blank...
Page 211: ...Specifications 211 External Diagrams 1 HX S 030 200G2 F I...
Page 212: ...Specifications 212 2 HX S 030 400G2 F I...
Page 213: ...Specifications 213 3 HX S 060 100G2 F I...
Page 214: ...Specifications 214 4 HX S 060 200G2 F I...
Page 215: ...Specifications 215 5 HX S 0120 50G2 F I...
Page 216: ...Specifications 216 6 HX S 0120 100G2 F I...
Page 217: ...Specifications 217 7 HX S 0400 15G2 F I...
Page 218: ...Specifications 218 8 HX S 0400 30G2 F I...
Page 219: ...Specifications 219 9 HX S 0500 12G2 F I...
Page 220: ...Specifications 220 10 HX S 0500 24G2 F I...
Page 221: ...Specifications 221 11 HX S 01000 6G2 F I...
Page 222: ...Specifications 222 12 HX S 01000 12G2 F I...
Page 223: ...Specifications 223...
Page 239: ......