Specifications
201
Constant Current Characteristics
Specification/Models
30-200
30-400
60-100
60-200
120-50
120-100
Range
0.0A -
210.0A
0.0A -
420.0A
0.0A -
105.0A
0.0A -
210.0A
0.00A -
52.50A
0.0A -
105.0A
Accuracy *12
±(0.5%+0.1A) of set
value
±(0.5%+0.2A) of set
value
±(0.5%+0.05A) of set
value
±(0.5%+0.1A) of set
value
±(0.5%+25mA) of
set value
(
0.5%+50mA
)
of
set value
Resolution
0.1A
10mA
100mA
Load Regulation *10
Below 0.05% + (0.01% of maximum output current)
Line Regulation *5
Below 0.05% + (0.005% of maximum output current)
Ripple (Effective Value)
*6
Below
200mArms
Below
400mArms
Below
100mArms
Below
200mArms
Below
50mArms
Below
100mArms
Temperature Coefficient
(Typical Value)
±200ppm/
℃
Specification/Models
400-15
400-30
500-12
500-24
1000-6
1000-12
Range
0.00A -
15.75A
0.00A -
31.50A
0.00A -
12.60A
0.00A -
25.20A
0.000A -
6.300A
0.00A -
12.60A
Accuracy *12
±(0.5%+10mA) of
set value
(
0.5%+20mA
)
of set
value
±(0.5%+5mA) of
set value
(
0.5%+10mA
)
of set
value
±(0.5%+3mA) of
set value
(
0.5%+6mA
)
of
set value
Resolution
10mA
100mA
10mA
1mA
10mA
Load Regulation *10
Below 0.05% + (0.03% of maximum output current)
Line Regulation *5
Below 0.05% + (0.005% of maximum output current)
Ripple (Effective Value)
*6
Below
15mA
Below
30mA
Below
10mA
Below
20mA
Below
5mA
Below
10mA
Temperature Coefficient
(Typical Value)
±200ppm/
℃
Note: *4: Measurement at sensing point for 0~100% change in rated load current (Static Load Change)
*5: For ± 10% change in input voltage (Static input Change)
*6: At measurement frequency band of 20Hz~1MHz (Resistance Loaded)
*7: Measured with oscilloscope at measurement frequency band of 20Hz~20MHz
*8: Recovery time within 0.1%+10mV of rated output voltage for 50% to 100% abrupt change in rated load current (Dynamic
Load Change)
*9: Time in which set voltage error is reached within 1% due to setting changes via panel operation or communication control or
external analog control.
*10: Current change value at the rated output current when load resistance is changed until resistance value outputs 0~rated
power (Static Load Change)
*11: At output open-circuit and environmental temperature 23
C
± 5
C
*12: At output short-circuit and environmental temperature 23
C
± 5
C
Summary of Contents for HX-S-01000-12G2
Page 165: ...Special Loads 165 This page is blank...
Page 169: ...Maintenance 169 This page is blank...
Page 211: ...Specifications 211 External Diagrams 1 HX S 030 200G2 F I...
Page 212: ...Specifications 212 2 HX S 030 400G2 F I...
Page 213: ...Specifications 213 3 HX S 060 100G2 F I...
Page 214: ...Specifications 214 4 HX S 060 200G2 F I...
Page 215: ...Specifications 215 5 HX S 0120 50G2 F I...
Page 216: ...Specifications 216 6 HX S 0120 100G2 F I...
Page 217: ...Specifications 217 7 HX S 0400 15G2 F I...
Page 218: ...Specifications 218 8 HX S 0400 30G2 F I...
Page 219: ...Specifications 219 9 HX S 0500 12G2 F I...
Page 220: ...Specifications 220 10 HX S 0500 24G2 F I...
Page 221: ...Specifications 221 11 HX S 01000 6G2 F I...
Page 222: ...Specifications 222 12 HX S 01000 12G2 F I...
Page 223: ...Specifications 223...
Page 239: ......