9
* Test the water flow and inspect the following items. The hot water may be slightly tainted at the start of
the water flow test, however this does not indicate any problem.
ⅰ
) Is there no water leaking from the pipe joints?
The pipe joints may come loose during transportation, so check all the joints in the basin body.
ⅱ
) Are the hot water supply and water supply pressures at the same, stable pressure?
ⅲ
) Is temperature be controlled properly?
ⅳ
) Check that the shower outlet flow is sufficient, by the following as a guide for flow rate.
①
Install water stop valve to installed hot water / water supply.
*Mount the water stop valve as the picture below and it is easy to open and close water with knob.
(Knob should be toward outside.)
②
Attach flexible pipes to check valves.
*Don’t connect the hot water and water in reverse.
*Make sure to use the provided packings.
③
Attach flexible pipes to water stop valves.
*Make sure to use the provided packings.
(Single tap type)
(double tap type)
④
Test water flow
⑤
Conduct water drain test. Check there is no leakage from the joint of the drain hose.
3
Connecting hot water and water supply pipe
Water stop valve[R1/2×G1/2]
Installed hot water
/ water supply pipe
Packing
Packing
Flexible pipe[L=200]
Check valve
Packing
Packing
Flexible pipe[L=200]
Hot water
Water
Check valve
Caution
Caution
Test the water flow before use to prevent accidents.
Drain test must be conducted in order to prevent water leakage during operation.
Installed hot water
/ water supply pipe
Hot water
Water
Hot water
Water
Hot water
Water
Water stop valve[R1/2×G1/2]
Hot water supply pressure, water supply pressure : 0.1 MPa each
Shower outlet temperature
: 40˚C
Shower head
: Approximately 8 L/min