background image

The following are parts that must be replaced on a regular basis as designated by our company:
Ƒ'UDLQKRVH5HSODFHHYHU\WKUHH\HDUV
-For the drain hose, there is a possibility that water leaks will occur because cracks are caused due to 
  deterioration and hardening of the hose from chemical agents in the drain water.
'DPDJHWRWKHKRVHPD\UHVXOWLQZDWHUIORRGLQJRQRUEHQHDWKWKHIORRU
Ƒ&KHFNYDOYH5HSODFHHYHU\WKUHH\HDUV
:KHQWKHFKHFNYDOYHLVXVHGFRQWLQXRXVO\IRUORQJSHULRGVRIWLPHWKHUHLVDSRVVLELOLW\WKDWWKHSDUWVLQ
WKHYDOYHZLOOGHWHULRUDWHUHVXOWLQJLQQRZDWHUGLVFKDUJLQJRUVRPHWLPHVWKHVHZDJHZDWHURQFH
   discharged from the water faucet will flow back, thus causing contamination of city water or public health 
   problems.
Ƒ:DWHUKRWZDWHUVXSSO\KRVH5HSODFHHYHU\WKUHH\HDUV
)RUWKHZDWHUKRWZDWHUVXSSO\KRVHWKHUHLVDSRVVLELOLW\WKDWFUDFNVGXHWRGHWHULRUDWLRQFDXVHGE\
   equipment operation or residual chlorine or copper ions in the city water will cause water leaks.
'DPDJHWRWKHKRVHPD\UHVXOWLQZDWHUIORRGLQJRQRUEHQHDWKWKHIORRU
7KHDERYHOLVWHGSDUWVPXVWEHUHSODFHGRQDUHJXODUEDVLVWRHQVXUHDQGPDLQWDLQVDIHW\DQGSHUIRUPDQFH

$Q\SDUWWKDWLVRXWVLGHWKHGHVLJQDWHGUHSODFHPHQWSHULRGPXVWEHUHSODFHGHYHQLIWKHUHLVQRSUREOHP

GXULQJXVH7KHSDUWVDUHDYDLODEOHDWDGGLWLRQDOFRVW2XUFRPSDQ\ZLOOQRWDVVXPHUHVSRQVLELOLW\IRUDQ\

harm, damage, or defects attributed to any part that was not replaced within the designated period.

For ordering replacement work, contact your closest dealer.

22

Daily Inspections

z

 To ensure that this product can be used for a long period of time, follow the procedures outlined in 

3URFHGXUHVIRU'DLO\,QVSHFWLRQVRQSDJHWRRIWKLVLQVWUXFWLRQPDQXDO

$OZD\VLQVSHFWWKLVSURGXFWIROORZLQJWKHSURFHGXUHVRXWOLQHGLQ3URFHGXUHVIRU'DLO\,QVSHFWLRQV
&RQWLQXLQJWRXVHWKLVSURGXFWZLWKRXWSHUIRUPLQJWKHGDLO\LQVSHFWLRQVPD\FDXVHPDOIXQFWLRQVRU
accidents.

Parts Replaced on a Regular Basis

Standard Duration of Use

7KHVWDQGDUGSHULRGRIXVHRIWKLVSURGXFWLVVHYHQ\HDUV

The standard period of use is "a guide for the standard period that this product can be used properly from 

DVDIHW\SHUVSHFWLYHZKHQFRQGXFWLQJDSSURSULDWHPDLQWHQDQFHDQGLQVSHFWLRQVLQFOXGLQJUHSODFHPHQWRI

SDUWVIRUWKHVWDQGDUGXVDJHFRQGLWLRQVIRUHDFKSURGXFW7KLVLVQRWWKHVDPHDVWKHZDUUDQW\SHULRG

Summary of Contents for RS Adria II

Page 1: ...rocedures for Daily Inspections Thank you for purchasing this Takara Belmont product The instructions contained in this booklet should be thoroughly read and understood before use Using this product b...

Page 2: ...FDXWLRQV DUH LPSRUWDQW IRU HQVXULQJ VDIHW GKHUH WR WKHVH SUHFDXWLRQV DW DOO WLPHV 7DNDUD HOPRQW LV QRW responsible for any damage or risk to the person using this product or those around them due to a...

Page 3: ...VW QRW EH FRQGXFWHG E SHRSOH RWKHU WKDQ TXDOLILHG UHSDLU WHFKQLFLDQV DLOXUH WR IROORZ WKLV LQVWUXFWLRQ PD FDXVH HOHFWURFXWLRQ ILUH RU DEQRUPDO RSHUDWLRQ OHDGLQJ WR LQMXU DVLQ 7LOW 6SHFLILFDWLRQ 7R DGM...

Page 4: ...t for non hairdressing work This product is an industrial product designed for barbers and hair salons Only use this product for its intended purpose and do not use it for non hairdressing work Failur...

Page 5: ...ompound Do not use an abrasive compound to clean the water faucet fixtures showerhead showerhead receptacle water stop knob and temperature control knob Use of an abrasive compound sponge with abrasiv...

Page 6: ...mpletely Failure to turn the water off completely may cause water leakage Do not wet the shower head bracket with water Do not wet the shower head bracket with water Failure to follow this instruction...

Page 7: ...d in water If pressure in the water pipes decreases due to repairs that follow water stoppages the water in the basin may flow back through the shower head Do not move the basin with water filled Be s...

Page 8: ...ct with newspaper or printed paper may cause stains Direct contact with items of clothing such as printed images of t shirts or jeans may cause discoloration of the synthetic leather of this product D...

Page 9: ...oduct Precautions on Resin Plated Parts Example of Flaws on the Plated Surface Example of Peeling of the Plated Surface Check to ensure that there are no flaws cracks or peeling of the plated surface...

Page 10: ...outer side of the basin 1 Secure the hooks of the neck cushion to the fixing pins on the inner side of the basin 2 3 Neck cushion 1 QVWDOODWLRQ LQVWUXFWLRQV 2SHUDWLQJ Manual 1 Setting sheet 1 6KRZHUKH...

Page 11: ...move the basin be sure to hold it at the leading and the trailing end of the basin as illustrated Failure to take this precaution may result in operational failure Move the basin position according to...

Page 12: ...in cap Rotate the screw in the counterclockwise direction When basin movement is heavy Rotate the screw in the clockwise direction When basin movement is light Rotate the basin adjustment screw provid...

Page 13: ...t Discontinue use and contact with your closest dealer z A gushing sound may be emitted from the main body depending on the environment or conditions that it is used in This sound is due to water flow...

Page 14: ...sing the product and contact your closest dealer Continued operation may result in personal injury Note For safety reasons this product is designed so that hot water of approximately 53 or higher is n...

Page 15: ...the lid may accidentally close and the water may overflow the basin from the failure to notice water discharge thus resulting in water leaks z Do not leave the showerhead in the water Water may flow b...

Page 16: ...her without cleaning can cause the drain to become blocked with hair leading to water overflowing and unhygienic conditions Try to clean the hair catcher after each shampoo Caution Be sure to execute...

Page 17: ...ng if degradation causes water to leak quickly when the basin is filled with water available at additional cost Drain cap Gasket Drain cap The drain cap should be handled carefully It may break if it...

Page 18: ...eather cleaners are to be used first check that there is no discoloration by testing in an area that is not visible Clean the leather every day after work Leaving dirt uncleaned may cause mold to grow...

Page 19: ...nit with water Remove dirt such as water deposits in the shower holes on the sprinkling filter unit with a toothbrush 3 Clean the air bubble unit with water Clean the unit once a month as a general gu...

Page 20: ...by removing dust and dirt tighten the drain nut firmly DUQLQJ The hot water supply pipe may become very hot Take care not to touch the pipe directly Check Valve Stink Trap Drain Nut Water Container W...

Page 21: ...ree latches on the main unit First hook the top latch and then hook the bottom two latches Caution Check that the maintenance cover is properly secured with the three latches If not water may penetrat...

Page 22: ...HG SDUWV PXVW EH UHSODFHG RQ D UHJXODU EDVLV WR HQVXUH DQG PDLQWDLQ VDIHW DQG SHUIRUPDQFH Q SDUW WKDW LV RXWVLGH WKH GHVLJQDWHG UHSODFHPHQW SHULRG PXVW EH UHSODFHG HYHQ LI WKHUH LV QR SUREOHP GXULQJ X...

Page 23: ...lacement of these parts is not covered by warranty and a fee will be required The level and period of wear degradation or damage may differ depending on the environment and conditions that the custome...

Page 24: ...When disposing of this product or replaced parts adhere with current regulations and dispose of them appropriately After sales Service To request after sales service contact your closest dealer or Ta...

Page 25: ...charge 8 0 L min Mixing type Neck height Thermostat type Basin free tilt type PRIME ELITE RS Adria II 864 951 mm Outside Dimensions See the Product Dimensions on page 26 Part Number AY P069X SU 191BW...

Page 26: ...cushion height 132 653 1525 95 418 5 500 4 6 1 361 460 566 446 1 2 Center of Drain Pipe 210 400 8 565 554 Standing Posture 2560 or over Sitting Posture 2590 or over Practice in Standing Posture 600 o...

Page 27: ...there is abnormal noise or the water does not turn off properly when the water stop knob is closed firmly there may be a malfunction in the stop valves of the water stop knob Is water output from the...

Page 28: ...W PXVW EH LQVSHFWHG DIWHU FORVLQJ IRU WKH GD Is there any water leaking within the basin 5HPRYH WKH EDVLQ PDLQWHQDQFH FRYHU DQG FKHFN WKDW WKHUH LV QR water leaking from the internal pipes or water ta...