Problem
Check Points
Recovery Procedures
■
Chair does not move.
■
The power switch turns
off when using the
service outlet.
■
Is the power plug
correctly inserted?
■
Is the power switch
turned on?
■
Has a fuse of the shop's
switchboard or breaker
been tripped?
■
Has the chair been
continuously operated
for an extended period?
■
Is the current used the
rated current?
・
12A or less
(110V/120V AC)
・
7A or less
(220V/230V/240V AC)
(North America:120V AC)
■
Has there been a short
circuit in one of the
devices connected to the
service outlet?
■
The breaker function operates if
the current used exceeds rated
current. Use an amount of current
that is less than the rated capacity,
and turn on the power again so that
the chair will operate normally.
(p. 26)
■
Switch to using a different device
and try turning on the power
switch. If the power cannot be
turned on when using a different
device, contact your closest dealer
or Takara Belmont.
■
Correctly insert the power plug.
(p. 11)
■
Turn on the power. (p. 12)
■
Replace the fuse of the
switchboard or turn on the breaker.
■
The problem is due to the
operation of the overheating
prevention device.Leave the chair
for approximately 10 min. to allow
it to return to the normal condition.
Is the switchboard
operating normally?
Might there
be a short
circuit?
Rated current?
Overheating Prevention Device
Breaker Function
Is the power
plug correctly
inserted?
Is the power
turned on?
If any of the problems described below occur, conduct the checks outlined before requesting repair.
These are not malfunctions
■
Abnormal sound at startup
■
Sound when rotating the chair
BEFORE REQUESTING REPAIR
29
■
Such sound is due to the internal hydraulic
fluid being cold and is not a functional
fault. It will readily stop.
■
This is the sound of the steel balls rolling
when the chair is rotated. The level of this
sound varies depending on the environment
where the chair is installed.
If any of the problems described above are inspected and the chair does not work normally
even after performing the recovery procedures, immediately stop using the chair, turn off the
power, unplug the power plug, and contact your closest dealer or Takara Belmont.
This is a protective function that
prevents damage to devices due to
using a current that exceeds the
rated current.
This is a protective circuit that
prevents abnormal overheating of
internal mechanisms due to
continuous operation and similar
causes. The chair might stop
moving temporarily.
Click!
Snap!
Summary of Contents for LEGEND